00190529-02.pdf - 第23页
SI PLACE 80 F Retrofitting Instructions ICPW 20 Nozzle Changer for 1 C Head Edition 11 / 97 1.4 Preparatory Work • Switch off the machine . • Remove the feeders from the components table . • Remove , if fitted , the waff…

Edition
11
/
97
SI
PLACE
80
F
Retrofitting
Instructions
ICPW
20
Nozzle
Changer
for
IC
Head
1.3
.
1
Definitions
Qualified
or
adequately
trained
personnel
:
Persons
who
are
familiar
with
setting
up
,
operating
and
maintaining
the
placement
machine
and
who
pos
-
sess
a
corresponding
qualification
,
such
as
for
example
:
•
Training
or
instruction
and
authorization
regarding
switching
out
,
disconnecting
,
grounding
or
labelling
circuits
and
installation
sections
in
accordance
with
applicable
safety
standards
.
•
Training
or
instruction
in
accordance
with
applicable
safety
standards
regarding
the
care
and
use
of
ap
-
propriate
safety
equipment
.
•
Training
in
first
aid
.
A A A
DANGER
within
the
intention
of
these
retrofitting
instructions
means
that
serious
injury
,
death
or
considerable
damage
to
property
will
result
if
the
notes
relating
to
danger
are
not
observed
.
A A
WARNING
within
the
intention
of
these
retrofitting
instructions
means
that
serious
injury
,
death
or
considerable
damage
to
property
could
result
if
the
warning
notes
are
not
observed
.
A
CAUTION
within
the
intention
of
these
retrofitting
instructions
means
that
light
injury
or
damage
to
property
can
result
if
the
caution
notes
are
not
observed
.
NOTE
within
the
intention
of
these
retrofitting
instructions
provides
important
information
concerning
the
product
or
that
part
of
these
retrofitting
instructions
to
which
particular
attention
is
to
be
drawn
.
Page
2
of
16

SI
PLACE
80
F
Retrofitting
Instructions
ICPW
20
Nozzle
Changer
for
1
C
Head
Edition
11
/
97
1.4
Preparatory
Work
•
Switch
off
the
machine
.
•
Remove
the
feeders
from
the
components
table
.
•
Remove
,
if
fitted
,
the
wafffepack
changer
.
•
Remove
the
cover
between
the
board
conveyor
and
the
components
table
.
•
Remove
the
flap
opener
and
the
tape
guide
place
,
•
Remove
the
components
table
,
disconnecting
all
plug
-
in
connections
.
•
Remove
the
waste
tape
chute
and
the
tape
cutter
.
1.5
Remove
the
copianarity
module
(
if
fitted
)
and
the
IC
camera
Fig
.
1.1
Removing
the
copianarity
module
and
the
IC
camera
•
Undo
the
two
mounting
screws
(
2
x
M
4
x
12
)
for
the
copianarity
module
(
see
Fig
.
1.1
)
and
lift
the
copiana
-
rity
module
upwards
and
out
of
the
machine
.
Page
3
of
16

Edition
11
/
97
SIPLACE
80
F
Retrofitting
Instructions
ICPW
20
Nozzle
Changer
for
IC
Head
•
Unscrew
the
two
screws
(
2
x
M
4
x
10
)
holding
the
connector
block
and
the
four
screws
(
4
x
M
6
x
20
)
hol
-
ding
the
support
for
the
coplanarity
module
.
•
Carefully
pull
out
the
cable
for
the
IC
camera
until
you
can
lay
the
support
for
the
copianarity
module
flat
on
the
floor
.
NOTE
All
necessary
work
,
adjustments
and
instructions
on
fitting
the
coplanarity
module
will
be
found
in
the
co
-
planarity
module
retrofitting
instructions
.
•
Remove
the
IC
camera
.
1.6
Fitting
the
ICPW
20
Nozzle
Changer
•
Unscrew
and
remove
the
old
carrier
nozzle
changer
from
the
base
plate
.
•
Unscrew
the
four
screws
(
4
x
M
8
x
20
)
holding
the
base
plate
and
remove
it
from
the
machine
.
•
If
the
base
plate
is
not
as
yet
fitted
with
pins
,
insert
the
supplied
pins
into
the
base
plate
.
•
Fit
the
new
carrier
nozzle
changer
firmly
on
the
new
base
plate
(
fitted
with
pins
)
.
•
Using
the
screws
you
have
removed
(
4
x
M
8
x
20
)
screw
the
new
base
plate
loosely
in
place
.
Page
4
of
16