00198536-02_AI_Mixed-Mode_TX2iV1_TX2V2_de_en.pdf - 第124页
4 Appendix 4.1 Excerpts from the Service Manual 124 Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019 Fig.78: Removing the lifting mechanics ► Dismantle the lifting mechan…

4 Appendix
4.1 Excerpts from the Service Manual
Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019 123
Overview
Fig.76: COT‑i parts
The COT-i for SIPLACE TX V2 machines is
split into three separate parts (units) which
are mounted directly to the machine base.
These parts are as follows:
1. Lifting mechanics left
2. Lifting mechanics right
3. COT-i central unit
The parts are directly fixed with eight screws
to the machine base (four screws at the
COT-i central unit and two screws on each
of the lifting mechanics).
Removal of left and right lifting mechanics
NOTICE
Shown by example
The following procedure is shown by example of the left lifting mechanics. The procedure
for the right lifting mechanics the same. Relevant differences will be mentioned.
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}77]
Fig.77: Locking flap
The safety bolt(1) fixes the connection
between the pneumatic cylinder and the lift-
ing mechanics.
► Flip the safety catch down.
► Remove the safety bolt, to access the
connection.
CAUTION!
Pay attention to the position and
number of washers used.
.

4 Appendix
4.1 Excerpts from the Service Manual
124 Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019
Fig.78: Removing the lifting mechanics
► Dismantle the lifting mechanics by re-
moving the screws(1).
Fig.79: Lifting mechanics parts
► Take out the "left lifting mechanics
assembly" [03126040‑xx].
Fig.80: Safety switch
► Repeat for the right lifting mechanics if
necessary.
The procedure for the right lifting mechanics
is the same, the only difference being that
the safety switch(1) must be removed.
► Remove the two fastening screws(2) of
the safety switch.
CAUTION!
Do not loose the sleeves.
.

4 Appendix
4.1 Excerpts from the Service Manual
Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019 125
Removing the central unit
Before removing the central unit, make sure that the lifting mechanics on the left and right have
been removed (see above).
CAUTION
Heavy machine part!
The COT-i central unit is heavy. To lift it out, you will need to use the mounting tool and a
suitable lifting device (hand-operated crane etc.).
Fig.81: Central unit connections
► Unplug all electrical(1) and pneumatic
connections(2) from the COTi. You
might like to mark their positions to
make clear assignment easier later on.
Fig.82: Central unit fastening screws
► Remove the four fastening screws(1).
► Remove the central unit out of the
machine.