4 Appendix
4.1 Excerpts from the Service Manual
Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019 129
Fitting the nozzle changer
Fig.87: Jumper
► Set the jumper(1) on the nozzle
changer to 2-3.
► Fix the nozzle changer onto the two holders with four screws.
► Calibrate the position of the nozzle changer.
4.1.3.5 Replacing the nozzle station
Parts
Fig.88: Nozzle station
Machine types Item no. Designation
1 SIPLACE TX1/TX2 V2 03090348-xx Nozzle station CPx complete / X4iS, XS
2 SIPLACE TX2i V2 03135777-xx Nozzle station assembly
All 03039514-xx Shim plates: support for nozzle reject
device
Equipment and tools
00353832-xx Allen key set
03079617-xx Depth measuring gauge (300mm)

4 Appendix
4.1 Excerpts from the Service Manual
130 Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019
Overview
Fig.89: Nozzle stations
1. Nozzle station with reject bin for
SIPLACE C&P20P2 and SIPLACE
CPP without stationary camera
2. Nozzle station with reject bin for
SIPLACE CPP with stationary camera
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}77]
Fig.90: Nozzle station for SIPLACE TX1/TX2
Fig.91: Nozzle station for SIPLACE TX2i V2
► Remove the two screws(2) fastening the nozzle station(1).
► Disconnect the hose (3).
► Remove the nozzle station.

4 Appendix
4.1 Excerpts from the Service Manual
Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019 131
Setting the installation height
► Set the correct installation height for the nozzle station as follows:
DANGER
Strong permanent magnet fields
Observe the safety instructions in section 1.1.2 "Safety instructions for working with strong
magnetic fields" [}74].
Fig.92: Overview of the measurement procedure
(example of standard nozzle station used)
Overview of measurement procedure
1. Distance
NOTICE!
Alternatively, you can measure from
the top edge of the lower guide rail of
the gantry.
.
► During the following inside measurement make sure that the tip of the measuring scale does
not touch the magnetic strip as this might scratch it!
CAUTION
Strong magnetic forces
► Place a suitable plastic plate between the magnet and measuring scale, if required.
► Position the measuring scale onto the upper edge of the X axis top linear guide and measure
the distance to the nozzle station contact surface. Hold the measuring scale vertically for this.
► Compare the measurement (1) with the target value (see table).
If needed, adjust the height by removing or adding NC shim plates.
Distance
Default:
Measure from the upper edge of the top linear guide
268 +0.1/-0.3 mm
Alternatively:
Measure from the upper edge of the bottom linear guide
107 +0.1/-0.3 mm
CAUTION
Crash hazard!
Do not place too many shim plates underneath.
NOTICE
Mixed mode option
In contrast to the nozzle changer, the nozzle station is not positioned lower down in the
mixed mode option.