SIPLACE S-23 HM User Manual.pdf - 第15页
15 Switc hing on the SI PLAC E line Switching on the line computer ● Switch on th e uninte rruptible powe r supply (UPS). The line com puter so ftware is uploaded . The login dialog window appears on the scree n after ap…

14
On-screen display - control box
In the control box you can activate or deactivate options. Activated options
are indicated by crosses in the check boxes. You can activate or deacti-
vate options by clicking on the check box with the mouse pointer. Click on
Accept to save the settings you have selected or discard them by pressing
Cancel. Click on the Help button to activate on-line help.
Please note, that you will need the line engineer access authorization for
certain options and that these options can only be activated or deactivated
by persons with that authorization.
On-screen display - selection box
● Click on the option you want and confirm your choice by pressing OK. You
can discard your choice by clicking on Cancel. Click on the Help button to
activate on-line help.

15
Switching on the SIPLACE line
Switching on the line computer
● Switch on the uninterruptible power supply (UPS).
The line computer software is uploaded.
The login dialog window appears on the screen after approximately 2 min-
utes.
● Enter
plr
in the "login" box and confirm your entry by pressing the
RETURN key.
● Enter the password in the "Password" box and press the RETURN key. If
no password is required, then just press the RETURN key.
The desktop (starting window) will appear on screen after approximately 3
minutes with the overlying login box.
● Enter the user name defined for your user account in the "User" box, and
enter the corresponding password in the "Password" box.
● Click on Ok to confirm. The functions of the line computer program can
now be executed according to your access rights.
Starting the stations
ATTENTION
Do not switch on the stations and peripherals until the Desktop menu is
displayed on the monitor of the line computer. Failure to observe this may
result in communications problems.
Before you switch on the machine ...
● Carry out a visual inspection of the machine. In particular make sure that
there are no obstacles within the range of movement of the gantries.
● Make sure that the z axes of all heads are in their top end positions.
● Check that the power and compressed air supplies are connected.
● Switch on the machine at the main switch. With the line computer con-
nected and provided there are no communication problems the main
menu for the user class Operator will appear.

16
● When the prompt appears on screen, press one of the white Start buttons
on the input/output side or on the left or right operating panel.
The placement system is ready for use again as soon as the reference
point run has ended.
Switching off the SIPLACE line
ATTENTION
Before you switch off the line make sure of the following:
– All placement and glueing operations must have been completed at the
stations.
– The z axes of all placement and glueing heads have to be in their top end
positions.
– No placement head should still be carrying components.
– All gantries must have moved to their waiting positions.
– The station computers are shut down safely.
Switching off the line computer
CAUTION
Never switch off the line computer simply by switching off the main switch.
Always shut down the operating system properly. If you fail to do so, you
may end up with considerable loss of data or corrupted programs.
● Position the mouse pointer at the top or bottom right-hand edge of the
screen. The pointer will become a cross.
● Hold the left-hand mouse button down. The main menu will appear.
● Still holding the mouse button down, move the pointer onto Shutdown
then release it. The following dialog box now appears on the screen.
● Click on Yes. The dialog box closes and the program is shut down. This
takes about one minute. The following box now appears:
● Switch off the UPS and the monitor.
Switching off the stations
When an automatic placement system is in use, NEVER just power it
off at the main switch (apart from in an emergency).
The station computer runs under the WINDOWS NT operating system.
You must shut down the operating system correctly before switching off
the station. The procedure for switching off the station is as follows:
● End all placement and gluing operations.
Really shut down ?
Yes No
Safe to power off
Press any key to reboot