SIPLACE DX1DX2-Spec-设备性能参数-EN-DMS.pdf - 第11页

11 Machine Concept Example of SIPLACE DX2 with WPC5/WPC6 PLEASE NOTE: For all po ssible head config- urations pleas e refer to section Mach ine Per- formance from page 12. DXT able 60 DX tabl e with 60 tracks DXT able 30…

100%1 / 76
10
Machine Concept
Example of SIPLACE DX2
PLEASE NOTE: For all possible head config-
urations please refer to section Machine Per-
formance from page 12.
DXTable 60 DX table with 60 tracks
CP20 SpeedStar head.
Other head configura-
tions possible.
NC Nozzle changer in acc.
with head configuration.
G1 Gantry 1
G2 Gantry 2
PA Placement area
11
Machine Concept
Example of SIPLACE DX2 with WPC5/WPC6
PLEASE NOTE: For all possible head config-
urations please refer to section Machine Per-
formance from page 12.
DXTable 60 DX table with 60 tracks
DXTable 30 DX table with 60 tracks
WPC Waffle Pack Changer,
type 5 or type 6
CP12 12 segment Col-
lect&Place head
Other head configura-
tions possible.
TH Twin Head.
NC Nozzle changer in acc.
with head configuration
IC Stationary camera
FC Flip chip camera
G1 Gantry 1
G2 Gantry 2
PA Placement area
12
Machine Performance
Placement head types SIPLACE SpeedStar (C&P20)
SIPLACE 12 segment Collect&Place (C&P12)
SIPLACE TwinStar (TH)
Placement performance
The placement performance is influenced by the different head combinations and head positions, plus the con-
veyor configurations. Individual options and customized applications also influence the placement performance.
On request, SIPLACE can calculate the actual performance of your product on your machine configuration.
IPC value [comp./h]
In line with the vendor-neutral conditions of the IPC 9850 standard published by the Association of Connecting
Electronics Industries.
SIPLACE Benchmark value [comp./h]
The SIPLACE benchmark value is measured during the machine acceptance tests. It corresponds to the condi-
tions specified in the SIPLACE scope of service and supply.
Theoretical maximum output value [comp./h]
The theoretical maximum output value is calculated from the most favorable conditions for each machine type
and setting, and corresponds to the theoretical conditions normally used in the industry.
Placement machine
SIPLACE DX2
Placement area IPC value Benchmark value Theoretical value
C&P20 / C&P20 48,000 60,000 67,750
C&P20/C&P12 31,000 43,000 53,000
C&P12/C&P12 25,500 31,000 41,000
TH/C&P12 16,500 18,500 25,000
Placement machine
SIPLACE DX1
Placement area IPC value Benchmark value Theoretical value
C&P20 24,000 30,000 33,875
C&P12 14,000 16,000 21,000
TH 5,100 5,500 6,500