SIPLACE DX1DX2-Spec-设备性能参数-EN-DMS.pdf - 第37页
37 01005 Placement In its standard version, the SIPLACE DX1/DX2 is designed for placement of 01005 components (0.4 mm x 0.2 mm). The SIPLACE component library already contai ns the contours and dim ensions of 01005 compo…

36
Vision Sensor Technology
PCB Position Recognition
Bad Board Recognition
Ink Spot Criteria
Methods • Synthetic fiducial recognition method
• Mean gray scale value
• Histogram method
• Template matching
Shapes and sizes of fiducials/structures for
synthetic fiducials
other methods
For dimensions of synthetic fiducials, see page
35
min. 0.3 mm
max. 5 mm
Masking material Good coverage
Recognition time Depends on the method: 20 ms - 200ms
Description
In the cluster technology
each subpanel is assigned
an inkspot.
If this is present during the
measurement via the PCB
vision module, the corre-
sponding subpanel is popu-
lated.
This function helps prevent
unnecessary costs caused
by placement of defective
panels.
Technical data for PCB position detection
PCB fiducials
Local fiducials
Library of bad panel recognition
Up to 3 (subpanels and multiple panels)
Up to 6 for the long board option (optional PCB fiducials
are output by the optimization.)
Up to 2 per PCB (may be of different type)
Up to 255 fiducial types per subpanel
Image analysis Edge detection method (singular feature) based on gray
scale values
Lighting method Front lighting
Fiducial recognition time 0.1 s
Field of vision 5.78 mm x 5.78 mm

37
01005 Placement
In its standard version, the
SIPLACE DX1/DX2 is
designed for placement of
01005 components
(0.4 mm x 0.2 mm).
The SIPLACE component
library already contains the
contours and dimensions of
01005 components. Spe-
cially developed component
nozzles of type 1005 are also
available for the SIPLACE
DX1/DX2. These are
adjusted to the shape and
size of the 01005 compo-
nents and have - as with all
other SIPLACE nozzles - a
highly wear-proof ceramic tip
and flexible nozzle seat. This
guarantees maximum preci-
sion and process reliability.
Optimized pickup is guaran-
teed by the ideal feeding
conditions in the SIPLACE X
feeder module. The smaller
the elements to be picked up,
the more accurate the pickup
needs to be.
Pickup is performed contact-
free to compensate minor
inaccuracies e.g. from com-
ponent or pocket tolerances
and to prevent mechanical
damage to the components.
The design of the SIPLACE
X feeder modules takes this
problem into account: new
motors and the reduced use
of fine mechanics help.
Small components can be
placed without perfor-
mance loss, with minimum
pitch and irrespective of the
larger components which are
next to the 01005 --compo-
nent. This equates to true
01005 capability. As a rule
with 01005 placement, a
finely tuned overall 01005
process is the basic require-
ment if you want to achieve
excellent results.
All the process parameters
must be optimized. The
SIPLACE team will be
pleased to advise you on
how to do this.
01005 measurement
results and ambient condi-
tions
As the dpm values and
pickup rates for 01005 place-
ment depend greatly on the
respective measuring condi-
tions, it is not advisable to
specify these without consid-
ering the corresponding
ambient conditions.
The following table shows typical values for 01005 placement,
which can be achieved with a SIPLACE DX1/DX2, provided
the relevant underlying conditions are fulfilled:
Machine type SIPLACE DX1 or
SIPLACE DX2
Placement head SpeedStar with component
camera type 23
Nozzle type 1005
Feeder module type 2x8mm SIPLACE X feeder
module
Station software 706.01 or later
SIPLACE Pro 10.0 or later

38
Machine Maintenance
We recommend that you
have your SIPLACE DX1/
DX2 serviced on a regular
basis to keep it in prime con-
dition during productive use.
The SIPLACE DX1/DX2
Maintenance Guide contains
recommendations for the
maintenance intervals. All
maintenance tasks are
explained in detail with clear
diagrams.
The maintenance intervals
are weekly, 3 monthly (only
when the SIPLACE is config-
ured with a C&P20 head)
and 6 monthly.
For simpler organization of
line maintenance during daily
production operations, the
degree of complexity is spec-
ified for each maintenance
task. These levels are minor
and major maintenance.
Weekly maintenance tasks
The weekly maintenance
tasks are simple minor
maintenance work. This
requires no special training
and can be performed by the
line operators, with the help
of the maintenance guide.
Weekly maintenance of one
DX line takes a maximum of
1 hour, an optimum proce-
dure can be much faster.
3 monthly and
6 monthly maintenance
tasks
The 3 monthly (only when
the DX1/DX2 is configured
with a C&P20 head) and 6
monthly maintenance tasks
are a combination of simple
and more complex major
work. We recommend that
you train your operating or
service personnel before
performing these more com-
plex tasks.
The 3 monthly and 6 monthly
maintenance can usually be
performed when the solder-
ing furnace for the line is ser-
viced.