51 Technical Data Electrical Ratings, Energy Consumption and Compressed Air Supply Electrical rating s Supply voltage Fu ses Main power supply 3 x 200 V~ ± 10 %; 50 Hz (North Japan) 3 x 220 V~ ± 10 %; 60 Hz (South Japan)…

100%1 / 76
50
Technical Data
Siemens Signal Interface
Signal Path
1. After switching on the station
Direction of transport
Conveyor n Conveyor n+1
PCB sensor PCB sensor
Station n transports PCB
to transfer position
Conveyor n running Conveyor n+1
Request
Transferred
Permission
Arrived
Request
Transferred
Permission
Arrived
Station n+1
is ready to receive
0
0
1
0
2. PCB transfer has started
Direction of transport
Conveyor n Conveyor n+1
PCB sensor
Station n transfers
PCB to station n+1
Conveyor n running Conveyor n+1 running
Request
Transferred
Permission
Arrived
Request
Transferred
Permission
Arrived
Station n+1 expects
PCB from station n
1
0
1
0
3. PCB is transferred
Direction of transport
Conveyor n Conveyor n+1
PCB sensor PCB sensor
Station n has just trans-
ferred PCB
Conveyor n stopped Conveyor n+1 running
Request
Transferred
Permission
Arrived
Request
Transferred
Permission
Arrived
Station n+1 expects PCB
from station n, PCB has
not yet arrived
0
1
1
0
PCB sensor
4. PCB transfer has been completed
Direction of transport
Conveyor n Conveyor n+1
PCB sensor PCB sensor
Station n
Conveyor n stopped Conveyor n+1 running
Request
Transferred
Permission
Arrived
Request
Transferred
Permission
Arrived
Station n+1
PCB has arrived
0
0
0
1
51
Technical Data
Electrical Ratings, Energy Consumption and
Compressed Air Supply
Electrical ratings
Supply voltage Fuses
Main power supply
3 x 200 V~ ± 10 %; 50 Hz (North Japan)
3 x 220 V~ ± 10 %; 60 Hz (South Japan)
3 x 208 V~ ± 10 %; 50/60 Hz (U.S.A)
3 x 230 V~ ± 10 %; 50/60 Hz
3 x 380 V~ ± 10 %; 50/60 Hz
3 x 400 V~ ± 10 %; 50/60 Hz (Europe)
3 x 415 V~ ± 10 %; 50/60 Hz
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 16 A characteristic C
3 x 16 A characteristic C
3 x 16 A characteristic C
Power connector
Cable 5 x 4 mm² 5 x 32 A (3 x 200 V~ / 208 V~ / 220 V~/ 230 V ~)
Cable 5 x 4 mm² with CEKON connector 5 x 16 A (3 x 380 V~ / 400 V~ / 415 V~/ V ~)
Energy consumption
Energy consumption
without vacuum pump
Energy consumption
with vacuum pump
a
a) Vacuum pump for C&P20 head only.
Nominal apparent
power
SIPLACE DX1
SIPLACE DX2
1.8 kVA
2.4 kVA
3.0 kVA
3.6 kVA
Nominal active power
SIPLACE DX1
SIPLACE DX2
1.2 kW
1.6 kW
2.0 kW
2.4 kW
Compressed air supply
Compressed air pres-
sure values
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure
0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air con-
nection
R 3/4" internal thread (pipe thread) with 1/2" hose connector
Compressed air consumption
b
b) Average consumption values.
Placement head
configuration
Compressed air
consumption-
c
without vacuum pump
c) Under normal atmospheric conditions at 20°C and 1013 hPa.
Compressed air consumption
c
with vacuum pump
a
SIPLACE DX2
SIPLACE DX1
C&P20 / C&P20
C&P20/C&P12
C&P12/C&P12
TH/C&P12
C&P20
C&P12
TH
490 Nl/min
520 Nl/min
550 Nl/min
375 Nl/min
280 Nl/min
275 Nl/min
100 Nl/min
200 Nl/min
100 Nl/min
Compressed air specification according to ISO 8573
Particle size (ISO Class 3)
5 µm
Particle density (ISO Class 3)
5 mg/m³
Maximum oil content (ISO class 1)
Particle density 0.01 mg/m³
Pressure dewpoint (ISO class 4)
Dewpoint + 3°
52
Technical Data SIPLACE DX1/DX2
Electrical Ratings, Energy Consumption and
Compressed Air Supply
1 = Electrical connection
2 = Compressed air connection
The connections are run into the machine from below and then connected to the power