SIPLACE DX1DX2-Spec-设备性能参数-EN-DMS.pdf - 第53页

53 Technical Data Dimensions and Setup Conditions Length 1450 mm Width S tandard configuration a a) Standard configuration: 1 DX table inside and 1 DX table outside. 2508 mm 2425 mm Height of the machine with indica tor …

100%1 / 76
52
Technical Data SIPLACE DX1/DX2
Electrical Ratings, Energy Consumption and
Compressed Air Supply
1 = Electrical connection
2 = Compressed air connection
The connections are run into the machine from below and then connected to the power
supply of pneumatic unit.
53
Technical Data
Dimensions and Setup Conditions
Length 1450 mm
Width
Standard configuration
a
a) Standard configuration: 1 DX table inside and 1 DX table outside.
2508 mm
2425 mm
Height of the machine
with indicator lamp
with folded-up protective covers
(for PCB conveyor height 900 mm)
(for PCB conveyor height 930 mm)
(for PCB conveyor height 950 mm)
max. 1765 mm
1980 mm
2010 mm
2030 mm
Machine ground clearance
(for PCB conveyor height 900 mm)
(for PCB conveyor height 930 mm)
(for PCB conveyor height 950 mm)
120 mm ± 15 mm
150 mm ± 15 mm
170 mm ± 15 mm
Weight
a
DX1 2x DX tables 60 (empty)
DX1 with 2x DX tables 60 (fully configured)
DX2 2x DX tables 60 (empty)
DX2 with 2x DX tables 60 (fully configured)
2482 kg
2806 kg
2532 kg
2856 kg
Location
a
SIPLACE DX1/DX2 3.71 m²
Load per unit area
a
The load per unit area calculation included an additional working
space of 0.5 m on each side of the machine.
SIPLACE DX1
SIPLACE DX2
6.1 kN/m²
6.2 kN/m²
Load per unit area
a
The load per unit area calculation includes an additional working
space of 1.0 m on each side of the machine.
SIPLACE DX1
SIPLACE DX2
4.7 kN/m²
4.8 kN/m²
Number of machine feet 4
Maximum noise emissions 75 dB (A)
Room temperature between 15°C and 35°C
Atmospheric humidity 30% to 75 % (no higher than 45% on aver-
age to prevent any possibility of condensa-
tion on the machine)
54
Technical Data
Placement System Dimensions