TM3200.Schedule task result displays_Manual.pdf - 第7页

SMT Software Eng ineering Group IM Operations Y AMAHA MOTOR CO., L TD.   MD OC-SOFT50138  7/13  [Kind of the Schedul e T ask that an error num ber and an err or occurred] Error number Content of error Kind of the Sc…

100%1 / 13
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50138
6/13
3.3. History Display
When this function is used, it indicates error information, logs of Schedule Task Result
message displayed after the Schedule Task on the [MIS] – [Error log] tab screen.
Error information is output with its error head number. The head number is displayed as /H1
/H2 in the [Details] row.
Fig.3.4 Error log screen
Information which head has error is output on "E
rror
log".
After Schedule Task finishes, execution result mess
information is output on "Error log".
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50138
7/13
[Kind of the Schedule Task that an error number and an error occurred]
Error
number
Content of error Kind of the Schedule
Task that an error
occurred
Ea7501 NOZZLE VACUUM LEVEL WARNING
Detected Illegal Vacuum Level.
Vacuum Check
Ea1048 NOZZLE CONDITION ERROR
As a result of vision recognition, the following nozzle
is concluded dirty.
Nozzle Condition Check
Es887 You can't move X or Y axis,
because some nozzles exist in the shaft cleaning
blow units.
Es891 You can't move X or Y axis,
because there isn't a shaft cleaning blow unit at the
bottom.
Es993 Nozzle detecting sensor on the shaft cleaning blow
unit detects something. (One shaft cleaning blow unit
exist. or two shaft cleaning blow units exist; and in
the case of a front shaft cleaning blow unit.)
Es994 Nozzle detecting sensor on the shaft cleaning blow
unit detects something. (Two shaft cleaning blow
units exist; and in the case of a rear shaft cleaning
blow unit.)
Ea7504 SHAFT CLEANING BLOW ERROR
- The designation of the blow position is out of a soft
limit range.
- The head lower-end sensor did not react with in the
fixed time, when the head downed.
- failed in nozzle exchange.
Ea7506 The machine stopped in shaft cleaning blow action
during operation.
Ea7518 The shaft cleaning blow cannot be executed
because of servo OFF or interlock error.
Shaft Cleaning Blow
(Attention 1) About the "Shaft Cleaning Blow", it is not output in the each head.
In addition, about the head number, it is not output either.
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50138
8/13
3.4. Schedule Task manual operation from the Schedule Task
monitor
In a reset state, you can execute "Shaft Cleaning Blow", "Nozzle Condition Check" and
"Vacuum Check" manually on the [Monitor] – [Schedule Task] tab screen.
Even with a manual execution of Schedule Task, execution results (OK and NG) are
displayed to the Schedule Task monitor.
(Attention 1) You can execute "Nozzle Condition Check" by clicking the "Check Nozzles"
button on the [Setup] screen.
(Attention 2) You can execute "Shaft Cleaning Blow" by the "Cleaning Blow" button on the
[Unit] – [Head] tab.
(Attention 3) About the dialog screen and the operation method to execute Schedule Task by
manual operation, refer to the manual text of each model.
Fig.3.5 The Schedule Task monitor screen