00198610-02_VD_712.1_R19-1_DE_EN.pdf - 第10页
Station Software 712.1 (R19-1) / Version Description 05/2019 Edition 10 4 Features of the 712.1 Station Software Version All features of the previous 7xx station software versions are also s upported in the 712.1 station…

Station Software 712.1 (R19-1) / Version Description 05/2019 Edition
9
3 Compatible Mode
Some station software versions may be used as lower versions in compatible mode. This means
that the new functions of the current version can be used in the compatible version as far as
possible.
The compatible mode is provided to operate stations with lower line software versions in order to
keep the line software version in case of a station upgrade.
The 712.1 station software version can be operated as Version 711.2© in compatible mode.
The visibility and functionality of the new functions in compatible mode are explained in the
following table.
Compatible Mode
Meaning
Complete
Complete function support.
Compatible
The function is visible and executable at the station. However, new add-
ons in the station software or in the line products are not supported.
Hidden
The function is invisible/inactive, e.g. due to licensing or unsupported
SIPLACE Pro download/upload.
Not supported
The function is not supported, e.g. because of failing hardware.
Table 3-1: Visibility and functionality in compatible mode
The respective visibility/functionality in compatible mode is specified for the new features in
chapter 4.
The compatible mode can be activated under Settings – SIPLACE station interface clients on
the GUI.
Please also refer to chapter 7.

Station Software 712.1 (R19-1) / Version Description 05/2019 Edition
10
4 Features of the 712.1 Station Software Version
All features of the previous 7xx station software versions are also supported in the 712.1 station
software version. The main new features of the 712.1 station software version are listed below.
NOTICE
Detailed information on the individual functions can be found in the Online help for the
station software.
4.1 OSC Package Option – Enhancements
Detailed information on the OSC Package features can be found in the OSC Package User Guide,
item no. [00198374-xx].
The main enhancements made for the OSC Package Option in the station software and SIPLACE
Vision are listed in the overview below.
Height Values for Snap-In and Pin-In-Paste Components Saved Machine-Dependently
Compatible mode: Complete
When restarting a machine, the height teaching step for snap-in / pin-in-paste components does
not need to be repeated. However, the height teaching step still needs to be repeated if attributes
of the board have been changed in SIPLACE Pro.
Placement of Critically Tall Components with Twin VHF or CPP Placement Head
Compatible mode: Hidden
It is possible to place several critically tall components. The collision typology model has been
extended to support this new feature.
The target head for critically tall components is either a CPP head in high head position or a Twin
VHF head. Which components are considered critically tall depends on the respective placement
head they are placed with.
Chipping Inspection
The component chipping detection functionality checks whether the edge of a component has
larger deviations than defined. It can be enabled or disabled using the Chipping inspection
checkbox in the Vision Inspection tab of the Component Shape Editor of SIPLACE Pro Desk.
Restrictions
– Only supported for vision types BareDie, BGA, CCGA, Chip, Moulded, Nonstandard.
– The OSC license must be available.
Station Software 712.1 (R19-1) / Version Description 05/2019 Edition
11
4.2 Robustness Package – Enhancements
Automatic Checking for Camera Soiling
Compatible mode: Complete
In Maintenance > Verification, the option Check for camera soiling has been added which can
be used to perform a check for soiled cameras.
When an illumination calibration is performed, the system will do an automatic checking for camera
soiling. If this is not desired, the automatic checking for camera soiling during an illumination
calibration can be turned off with the new option Skip check for soiling of all cameras in
Maintenance > Verification > Calibrate illumination.
Restrictions
– The check for camera soiling is implemented for the camera types SST23, 28, 29, 30, 38, 41,
45, 46, 48 and 49.
Changed Behavior for Errors on Alternative Components
Compatible mode: Complete
The needed operator actions for when a vision error occurs concerning alternative components has
been reduced.
Detection of Protruding Empty Tape
Compatible mode: Complete
It is possible that empty component tapes do not enter the tape channel which may cause head
crashes if not detected. To prevent this, special structures on the track ruler are measured to detect
any tapes not entering the tape channel.
Restrictions
– Component tapes not entering the tape channel can only be detected after some time has
passed during production. For the detection it is necessary that the fiducials are always within
the PCB camera field of view.
– The inspection can only be carried out on machines on which the track ruler has fiducial
structures (cross-shaped fiducials) printed on it.
Using Individual Pickup Error Thresholds for Components
Compatible mode: Hidden
The station software issues warning and error messages when pickup errors occur (including vision
errors). These warning and error messages are triggered by threshold values, which, by default,
are identical for all tracks. However, as of SIPLACE Pro 16.1 it is possible to configure these
threshold values individually in SIPLACE Pro, overruling the default values from the station
software.
The station software adopts the individual threshold values from SIPLACE Pro. If no individual
threshold values are specified, the default values from the setup configuration are used.