00198610-02_VD_712.1_R19-1_DE_EN.pdf - 第36页
Station Software 712.1 (R19-1) / Version Description 05/2019 Edition 36 Segment 1 was displayed. D1 -152642401 The Tray view automatically jumped to level 1 after the WPTC was confir med. D1 -152854501 The conveyor did n…

Station Software 712.1 (R19-1) / Version Description 05/2019 Edition
35
9 Corrected Errors
712.1 Station Software
The 712.1 station software version contains all error corrections of the previous 7xx versions.
Additionally, the following errors have been corrected in this version:
Error no.
Error description
G50005117
Machine crashes when plausibility check for fiducial fails.
G50015717
Compressed air deactivation does not work.
G50017432
Pin Picker does not put support pins back in the magazine.
G50017946
Placement bug.
G50019002
Calibration steps are missing after installing SIPLACE Smart Pin Support.
G50022073
No error distribution and help with frequent vision error.
GD1-153469701
Problems with teaching of Pickup Correction. The individual vision images are
not displayed correctly.
GD1-158641701
Not all the possible support pins have been placed.
GD1-158665601
The feed axis moves into the limit switch after calibration of pick-up position.
GD1-159509218
Board rotation cannot be determined with the selections.
GD1-160027001
Bench inspection TH is not executed even though the result shows it was
successful.
GD18744-4401
The open and closed vacuum is too low, even though the status is OK.
Table 9-1: Corrected errors station software version 712.1
712.0
Error no.
Error description
D1-142591801
An incorrect conveyor width was set after reboot.
D1-145486748
Various conveyor errors.
D1-146654832
During the height reference run, a nozzle was expected that was missing. The
nozzle could not be provided at the current activity level.
D1-148088101
The CPP placement head removed a component that was already placed by
the Twin VHF placement head.
D1-148126901
Width adjustment was performed during running production on a SIPLACE
TX2i placement machine.
D1-149428701
Night run with cyclic board transport stopped: disturbed CAN communication,
channel 1. Error message Placement status is unknown: Gantry 1,

Station Software 712.1 (R19-1) / Version Description 05/2019 Edition
36
Segment 1 was displayed.
D1-152642401
The Tray view automatically jumped to level 1 after the WPTC was confirmed.
D1-152854501
The conveyor did not function during machine endurance run.
D1-153279801
The stations within one line displayed different states (productive/blocked).
D1-153508601
Errors could not be selected in the error statistics view.
D1-154092217
Undefined hardware error after downloading Application 1; 5 DP axes without
Application 1.
D1-154781809
Stop threshold = 0 was ignored.
D1-155009601
At error 33263 Connection between GigE interface card in the
PC and the camera interrupted (252), the GUI did not display which
camera or gantry was affected.
D1-155170101
Glass plate with fiducials could not be calibrated with the SST47 board
camera.
D1-155523201
X4 S placement machine: FCCS digital – in PA1, the stop position of the tray
had a 5 cm back shift. The fiducials could not be recognized.
D1-155597201
Location 2 could not be approached by position correction.
D1-155619501
Stopping the production took too long.
D1-156262534
The software hung up and the module had to be restarted.
D1-156809701
The machine stopped during the 2h run (first board) after about 4 minutes
without any error message.
D1-157648601
After the table was removed and inserted, the feeder speed of the Xi Feeder
changed automatically.
D1-158062753
Extended Vision dump file was not stored.
D1-158064501
After starting the FCCS, the gantry never moved to the FCCS plate to start the
calibration.
D1-158433701
The Leveling assistant could not be performed.
D1-158465849
Leveling assistant error.
D1-159122707
The ACT measurements were not successful, because the distance check
failed.
D18495-4001
The XML file generated by Traceability had the wrong start time.
Table 9-2: Corrected errors station software version 712.0
Station Software 712.1 (R19-1) / Version Description 05/2019 Edition
37
10 Important Terms and Abbreviations
CA4
CA4 V2
Machine type of the Chip Assembly (CA)-series with 4 gantries
and 2 PAs
C&P
Collect & Place
CPP
Collect & Place & Pick & Place
DC
Dual Conveyor
DX1/DX2
Machine type with 1 or 2 gantries and 1 PA
DX4
Machine type with 4 gantries and 2 PAs
E1 L
E1 R
Machine type with 1 gantry and 1 PA
EDIF
Electronic Design Interchange Format
eWLP
embedded Wafer Level Process
FOPLP
Fan-Out Panel Level Packaging
FCCS
Field Camera Calibration System
GUI
Graphical User Interface
HFH
High Force Head
HW
Hardware
MGCU
Modular Gantry Control Unit
MHCU
Modular Head Control Unit
MTC
Matrix Tray Changer
OIS
Operator Information System
PA
Processing area
PCB
Printed circuit board
Placement mode:
2-in-1
When a machine runs in I-Placement mode, it is possible to
perform manual operations for one side / gantry. This placement
mode is also called "independent".
Placement mode:
Alternating
Placement mode in a dual gantry placement area, in which both
gantries place components on both boards in a dual conveyor.
First, both gantries place all assigned components on the board
in lane one and then on the board in lane two.
Placement mode:
Borrow
Performance
A line runs in I-Placement mode and to get a balanced
throughput between the left and right conveyor lanes, e.g. the
last machine runs in Alternating mode and places components in
this placement area on the board of the other lane.
Placement mode:
I-Placement
Placement mode in a dual gantry placement area in which each
gantry only places components on the board of the assigned
conveyor lane.
SC
Single Conveyor
SC
SIPLACE Setup Center (external setup control system)
SW
Software
SWS
SIPLACE Wafer System