Checking and Replacing Head Vacuum Filter
Step 5.
Remove by turning in the direction of the arrow Vacuum
Filter.
Step 6.
Release the emergency stop as described in "Releasing
'Emergency Stop' mode" on page 1-10 and perform the
operation again.
Caution
Check the vacuum filter every week and replace it within at least 6
months to ensure the vacuum for part pickup is generated properly.
Caution
It is recommended that the solenoid valve, which is a consumable
product, is replaced every two years to ensure stable operation.

Advanced Chip Shooter
MEMO
DECAN S2 Maintenance Handbook
4-8
Weekly Inspection

Monthly Inspection
chapter 5
Advanced Chip Shooter
DECAN S2 Maintenance Handbook
5-1
Cleaning Head Spindle
Tool for Maintenance
Cleaning liquid, ultra fine fiber cloth, air gun
Measures
Step 1.
Move the Front X Frame and Rear X Frame to both
ends by referring to "Forward movement of the front
X-frame" on page 1-3 and "Backward movement of the
rear X-frame" on page 1-7.
Step 2.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to "How to perform emergency stop" on page
1-2.
chapter 5
Monthly Inspection
Step 3.
Saparate the coil tube from vacuum filter
Cleaning Head Spindle
(Time required: 30min / No. M-1)