00191134-03.pdf - 第101页
GEM for SIPLACE V5.01 ©Siemens AG, all rights r eserved page 101 of 252 The high- order bit of ALC D will be "1" if this alar m is curr ently O n (Unsaf e), or "0" if it is currently Off ( Safe). T he…

GEM for SIPLACE V5.01
Page 100 of 252 ©Siemens AG, all rights reserved
The following special format can be used to enable or disable all ALIDs.
S5F3 [W] * H->E
<L [2]
<B [1] ALED> * ALED - Alarm Enable/Disable Code
<U4> * ALID - Alarm ID
> .
The Host may optionally set the W-Bit to "1" in S5F3. If so, the SIPLACE replies with
S5F4.
6)(QDEOH'LVDEOH$ODUP
S5F4 * H<-E
<B [1] ACKC5> . * ACKC5 - Acknowledge Code
ACKC5 Description
0x00 Normal. Everything Correct
0x01 Invalid ALID.
6)/LVW$ODUPV5HTXHVW
S5F5 W * H->E
<U4 ALID ...> . * Alarm ID Array
The Host requests the Equipment to send the current status of the specified Alarm IDs.
The Host can use the following special format to request the status of all Alarm IDs:
S5F5 W
<U4>. * ALID
6)/LVW$ODUP'DWD
S5F6 * H<-E, Multiblock
<L
<L [3]
<B [1] ALCD> * ALCD - Alarm On/Off and Severity
Code
<U4 ALID> * Alarm ID
<A ALTX> * ALTX - Alarm Text
>
...
> .

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 101 of 252
The high-order bit of ALCD will be "1" if this alarm is currently On (Unsafe), or "0" if it is
currently Off (Safe). The low-order seven bits of ALCD contain the severity code for this
alarm.
For any invalid ALID specified in S5F5, the corresponding entry in S5F6 has the following
special error format:
<L [3]
<B> * ALCD - alarm On/Off and Severity Code
<U4 ALID> * Alarm ID
<A> * ALTX - Alarm Text
>
If S5F5 specified all alarms, S5F6 reports alarms in order by alarm ID.
6)/LVW(QDEOHG$ODUPV5HTXHVW
S5F7 W . * H->E
The Host requests the Equipment to send the current status of all Alarm IDs which are
currently enabled (See S5F3).
6)/LVW(QDEOHG$ODUP'DWD
S5F8 * H<-E, Multiblock
<L
<L [3]
<B [1] ALCD> * ALCD - Alarm On/Off and Severity
Code
<U4 ALID> * Alarm ID
<A ALTX> * ALTX - Alarm Text
>
...
> .
The high-order bit of ALCD will be "1" if this alarm is currently On (Unsafe), or "0" if it is
currently Off (Safe). The low-order seven bits of ALCD contain the severity code for this
alarm.
S5F8 contains only those ALIDs which are currently enabled for reporting (See S5F3).
S5F8 reports alarms in order by Alarm ID.

GEM for SIPLACE V5.01
Page 102 of 252 ©Siemens AG, all rights reserved
6)$ODUP5HSRUW%ORFN6HQG
S5F71 [W] * H<-E
<L [2]
<U1 0> * ALPY Alarm Priority
<L [1]
<L [4]
<U4 ALID> * ALID - Alarm ID
<BOOLEAN ASTAT> * T = Alarm On
F = Alarm Off
<U4 ASER> * ASER Alarm Serial Number
<A [16] 'YYYYMMDDhhmmsscc'> * CLOCK
>
>
> .
1RWH7KLVPHVVDJHLVSURYLGHGRQO\IRUFRPSDWLELOLW\ZLWK+RVWFRPSXWHUVZKLFKVXSSRUW
DQROGHUYHUVLRQRI*(0
If the Equipment Constant "ConfigAlarms" is set to "1", the Equipment sends S5F71
instead of the normal S5F1 Alarm Notification Send.
The SIPLACE reports that an alarm condition has changed.
ALID identifies the Alarm.
ASTAT value is "True" (Non-zero) if this alarm is currently On (Unsafe), or "False" (Zero)
if it is currently Off (Safe).
ASER (Alarm Serial Number) is assigned by the Equipment. Its value begins at "1" and is
incremented by 1 for each alarm reported.
ALPY (Alarm Priority) is always zero.
CLOCK indicates the date and time of the alarm change.
Equipment Constant "Wbits5" controls whether the Equipment sends S5F71 with w-bit =
"1" (Reply Expected) or "0" (No Reply Expected).
6)$ODUP5HSRUW%ORFN$FNQRZOHGJH
S5F72 * H->E
<L> .
The Host acknowledges Alarm Report. This Equipment ignores the data portion of
S5F72.