00191134-03.pdf - 第66页
GEM for SIPLACE V5.01 Page 66 of 252 ©Siemens AG, all rights reserved 4 = busy , try later 5 = will not accept >5 other error 6 - 63 reserved used in: S7F2 33,' - Proces s Program ID Format: A[8] used in: S2F27, …

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 65 of 252
3LFN8S5HVXOW - Result of the pick up action
Format : U1
0 NOK (default value)
1 OK
2 NOK
used in : PLACEINFOREV1, PLACEINFOREV2
3LFN8S9DFFXP - Vaccum measured at pick-up position.
PickUpVacuum is measured in the pick up circuit after a component is picked up
Format : I4
Units are mbar
used in : PICKUPINFOREV1, PICKUPINFOREV2,
3LWFKBSHUBOHDGBJURXS- Distance between leads.
During the optical centering of a package the vision system calculate the average
distance between the leads within a lead group.
Format: I4
used in : PLACEINFOREV1, PLACEINFOREV2, VISIONDATAIC
3/$&((5525'(6&5,37,21 – Description of an placement error.
Format : U2
2 : Visionerror
3 : Vacuumerror
In case of both errors at the same time, a visionerror will be reported
3ODFHPHQW5HVXOW - Result of the placement action
Format : U1
1 : Component placed
2 : Component was thrown away, because of an detected error
used in : PLACEINFOREV1, PLACEINFOREV2
3ODFHPHQW9DFFXP - Vacuum measured during placement.
Format : I4
PlacementVacuum is measured in the placement circuit before the component is placed.
UNITS are mbar
used in : PLACEINFOREV1, PLACEINFOREV2
33%2'< - Process Program Body
Format: A
used in: S7F3, S7F6
33*17 - Process Program Grant
Format: B[1]
0=OK
1 = already have
2 = no space
3 = invalid PPID

GEM for SIPLACE V5.01
Page 66 of 252 ©Siemens AG, all rights reserved
4 = busy, try later
5 = will not accept
>5 other error
6 - 63 reserved
used in: S7F2
33,' - Process Program ID
Format: A[8]
used in: S2F27, S7F1, S7F3, S7F5, S7F6, S7F17, S7F20
357,' - Report ID
Format: U4
used in: S2F33, S2F35, S6F3, S6F9, S6F11, S6F13, S5F16, S6F18, S6F19, S6F21
4XDOLW\ - Measurement result of a package form or a fiducial
Quality ranges between 0 and 100. The higher the value, the better the fiducial was
recognized.
Format: U1
used in: PLACEINFOREV1, PLACEINFOREV2, FIDUCIALDATA
5&0' - Remote Command
Format: A
used in: SsF21, S2F41
5HDO1R]]OH/HQJWK - measured nozzle length
The nozzle length is measured during the reference run. It depends on the
HEIGHTREVOLER value. So REAL_NOZZLE_LENGTH is not a absolute but a relative
value.
It is calculated by subtracting the measured difference between the nozzle and the upper
edge of the conveyor belt from the HEIGHTREVOLER value.
Format: I4
Units are 1/1000 mm
5HIHUHQFH'HVLJQDWRU - Identifier for a placement position
Format: A
see chapter 5.4 in the SIPLACE Data Interface ( <position_name> in
<placemant_pos_record>).
used in: PLACEINFOREV1, PLACEINFOREV2, COORDINATEIC
5(3*6= - Reporting group size
Format: U4
used in: S2F23
56'$ - Request Spool Data Acknowledge
Format: B[1]
0=OK
1 = Denied, busy try later
2 = Denied, spooled data does not exist
3 - 63 reserved
used in: S2F24

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 67 of 252
56'& Request Spool Data Code
Format: B[1]
0 = Transmit Spooled Massages
1 = Purge Spooled Messages
2 - 63 reserved
6(*0(17 – Number of the segment to pick up or place a component.
Format: U1
6+($' - Stored header related to the transaction timer
Format: B[10]
used in: S9F9
603/1 - Sample number
Format : U4
used in: S6F1
62)75(9 - Software revision code
Format: A[6]
used in: S1F2, S1F13, S1F14, S1F65, S1F66
67,0( - Sample time
Format: A[16]
used in: S6F1
675$&. - Spool Stream Acknowledge
Format: B[1]
1 = Spooling not allowed for stream
2 = Stream unknown
3 = Unknown function specified for this stream
4 = Secondary function specified for this stream
used in: S6F44
675,' - Stream ID
Format: U1
used in: S2F43, S2F44
69,' - Status Variable ID
Format
used in: S2F23
691$0( - Status variable name
Format: A
used in: S1F12
7(;7 - A single line of characters
Format: A[160]
used in: S10F1, S10F3, S10F5, S10F9
7,$$&. - Equipment Acknowledge Code
Format: B[1]