00191134-03.pdf - 第58页
GEM for SIPLACE V5.01 Page 58 of 252 ©Siemens AG, all rights reserved used in: PLACEINFOREV1, PLACEINFOREV2, PICKUPINF OREV1 PICKUPINFOREV2, VISIONDAT AIC, COPLANARITYDAT AIC, INVENTARYW PC, PARTNRPLACEIC, &RSODQ DUL…

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 57 of 252
&((' - Collection event enable/disable code
Format: B[1]
False = Disable
True = Enable
&(,' - Collection event ID
Format: U4
used in: S2F35, S2F37, S6F3, S6F9, S6F11, S6F13, S6F15, S6F16, S6F17, S6F18
&/2&. - Clock YYYYMMDDhhmsscc
Format A[16]
used in: S5F71, S5F73, CLOCK, PICKUPDATARESETPOINT
FORVHGBQR]]OH Vacuum value for a nozzle
vacuum value measured with closed nozzle
Format: I4
Units are mbar
used in : VACUUMDATAREV1, VACUUMDATAREV2, VACUUMDATAIC
&0'$ - Command acknowledge code
Format: B[1]
0 = completed or done
1 = command does not exist
2 = cannot perform now
>2 = other equipment specific error
3- 63 reserved
used in: S2F22, S2F28
&RPS&RXQW Number of components per tray in the waffle pack changer
Format: I2
used in : INVENTARYWPC
&RPS/HIW3ODFH Number of components left to be placed on the actual PCB
Format: I2
used in : GANTRYINFO1, GANTRYINFO2, GANTRYINFOIC
&RPS3LFNHG8S Number of components which were picked up successfully since the
current PCB reached the center conveyor
Format: I2
used in : GANTRYINFO1, GANTRYINFO2, GANTRYINFOIC
&RPS3ODFHG Number of components which were placed since the current PCB
reached the center conveyor
Format:U4
used in : GANTRYINFO1, GANTRYINFO2, GANTRYINFOIC
&RPSRQHQW1DPH - Name of a component
Format: A

GEM for SIPLACE V5.01
Page 58 of 252 ©Siemens AG, all rights reserved
used in: PLACEINFOREV1, PLACEINFOREV2, PICKUPINFOREV1
PICKUPINFOREV2, VISIONDATAIC, COPLANARITYDATAIC,
INVENTARYWPC, PARTNRPLACEIC,
&RSODQDULW\(UURUV -Number of coplanarity errors since last download of a process
program
Format: U2
used in: PICKUPERRORS
&3$&. - Command Parameter Acknowledge Code
Format: B[1]
1 = Parameter Name does not exist
2 = Illegal value specified for CPVAL
3 = Illegal format specified for CPVAL
4 = PP not in library
>4 = other equipment specific error
4- 63 reserved
used in: S2F22, S2F28
&31$0( - Command Parameter Name
Format: A
used in: S2F41, S2F42
&39$/ - Command Parameter Value
Format:
used in: S2F41
FXELFBQR]]OH Vacuum value for a nozzle
threshold for cubic components
Format: I4
Units are mbar
used in : VACUUMDATEREV1, VACUUMDATAREV2, VACUUMDATAIC
'$7$,' - Data ID
Format:
used in: S2F33, S2F35, S2F39, S2F49, S6F3, S6F5, S6F9, S6F11, S6F13, S6F13,
S6F16, S6F18
'$7$/(1*7+ - Data Length
Format: U4
used in: S2F39, S6F5
'LYLVLRQ - Division at a feeder or a level in the waffle pack changer
Format: I2
used in: PICKUPINFO1, PICKUPINFO2, INVENTARYWPC, DIVISIONIC
'5$&. - Define Report Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. Insufficient space

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 59 of 252
2 = Denied. Invalid format
3 = Denied. At least one RPTID already defined
4 = Denied. At least one VID does not exist
>4 = Other errors
5 - 63 reserved
used in: S2F34
'63(5 Data Sample Period
Format: A
used in: S2F23
($& - Equipment Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. At least one constant does not exist
2 = Denied. Busy
3 = Denied. At least one constant out of range
>3 = Other errors
4 - 63 reserved
used in: S2F16
(&'() - Equipment Constant Default Value
Format:
used in: S2F30
(&0$; - Equipment Constant MaximumValue
Format:
used in: S2F30
(&0,1 - Equipment Constant Minimum Value
Format:
used in: S2F30
(&1$0( - Equipment Constant Name
Format:
used in: S2F30
(5$&. - Enable/Disable Event Report
Format: B[1]
0 = Accept
1 = Denied. At least one CEID does not exist
>1 = Other errors
2 - 63 reserved
used in: S2F38
)&1,' - Function Identification
Format: U1
used in: S2F43, S2F44