GEM for SIPLACE V5.01 ©Siemens AG, all rights r eserved page 27 of 252 3URFHVV6WDWHV The Proc ess State Diagram illus trates in detail the proc essing at the SIPLACE. Machine Initialization Single Function Processi…

GEM for SIPLACE V5.01
Page 26 of 252 ©Siemens AG, all rights reserved
Variable Name VID
OFFLINESUBSTATE 1002010
ONLINEFAILED 1002008
ONLINESUBSTATE 1002009
CONTROLSTATE 1002006
PREVIOUSCONTROLSTATE 1002007
5HODWHG(YHQWV
The following lists the collection events (CEIDs) which are relevant to the Control State.
For a more complete description of these events, see "Appendix B -- Collection Events" or
the description in this chapter.
Collection Event CEID
GemControlStateLOCAL 1000003
GemControlStateREMOTE 1000004
GemEquipmentOFFLINE 1000005

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 27 of 252
3URFHVV6WDWHV
The Process State Diagram illustrates in detail the processing at the SIPLACE.
Machine
Initialization
Single
Function
Processing
7
1
2
3
4
5
6
3URFHVV6WDWH'LDJUDP

GEM for SIPLACE V5.01
Page 28 of 252 ©Siemens AG, all rights reserved
6,3/$&(3URFHVV6WDWH7UDQVLWLRQV
# From Trigger To Description
1 Unknown Power-Up Machine
Initialization
At power-up, the Equipment
defaults to the 0DFKLQH
LQLWLDOL]DWLRQ state.
2 Machine
Initialization
Machine is
ready
Processing All data is available to
produce a board. All
peripheral equipment like
the Vision system is
initialized and the machine
has finished the reference
runs correctly. In this state
the machine will start its
work, when a PCB is put on
the input conveyor
3 Processing new Data form
the Host
Machine
Initialization
New production data is
send during the machine is
processing a board. The
board will be finished and
the machine will go to the
0DFKLQHLQLWLDOL]DWLRQ state
4 Machine
Initialization
a) Fatal Error
during machine
initialization
b) Stop-Button
on GUI
Single
Function
When a fatal error occurs
during machine initialization
it will automatically switch to
VLQJOHIXQFWLRQ mode.
In the case that the
operator press the Stop-
Button on the GUI, the
machine will first end the
board in the center
conveyor (if there is one)
and will then enter the
VLQJOHIXQFWLRQ mode.
5 Single
Function
Start-Button on
GUI
Machine
Initialization
When the machine is in
single function mode, the
operator press the Start-
button and the Prestate
was machine Initialization
the machine will return to
the 0DFKLQHLQLWLDOL]DWLRQ
state.
6 Processing a) Fatal Error
during machine
initialization
b) Stop-Button
on GUI
Single
Function
When a fatal error occurs
during processing the
machine will automatically
switch to VLQJOHIXQFWLRQ
mode.
In the case that the
operator press the Stop-
Button on the GUI, the
machine will first end the
board in the center
conveyor (if there is one)
and will then enter the
VLQJOHIXQFWLRQ mode.