00191134-03.pdf - 第159页
GEM for SIPLACE V5.01 ©Siemens AG, all rights r eserved page 159 of 252 9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ 1 = Equipment O ff -Line 2 = Attempt O n-Line 3 = Host Of f-Line 1002056 SV A OPERAT ORCMDINRMOT…

GEM for SIPLACE V5.01
Page 158 of 252 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
sending another. Valid values are 0-32000.s
1002004 EC U1 CONFIGCONNECT.
An EC which controls which SECS message this
Equipment will use for Connect Request.
0 = S1F1
1 = S1F65
2 = S1F13
Control State Model
1002005 EC U1 INITCONTROLSTATE.
Initial (power-up) control superstate.
1 = Off-Line
2 = On-Line
1002006 SV U1 CONTROLSTATE.
The current Control State.
1 = Off-Line/Equipment Off-Line
2 = Off-Line/Attempt On-Line
3 = Off-Line/Host Off-Line
4 = On-Line/Local
5 = On-Line/Remote
1002007 SV U1 PREVIOUSCONTROLSTATE.
The Control State in effect before the most recent
transition to the current Control State.
1 = Off-Line/Equipment Off-Line
2 = Off-Line/Attempt On-Line
3 = Off-Line/Host Off-Line
4 = On-Line/Local
5 = On-Line/Remote
1002008 EC U1 ONLINEFAILED.
The default Control State transition when Attempt On-
Line fails.
1 = Equipment Off-Line
3 = Host Off-Line
1002009 EC U1 ONLINESUBSTATE.
The default (power-up) online substate of the Control
State Model.
4 = Local
5 = Remote
1002010 EC U1 OFFLINESUBSTATE.
The default (power-up) offline substate of the Control
State Model.

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 159 of 252
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
1 = Equipment Off-Line
2 = Attempt On-Line
3 = Host Off-Line
1002056 SV A OPERATORCMDINRMOTESTATE
The last command issued by the Operator while the
Control state is „Remote“.
An empty text indicates that there was no operator
command in remote state since the last start of the
SIPLACE.
1002057 SV U1 CONTROLMODE
The actual control mode at the SIPLCAE. This SV
indicates which software system is allowed to
download placement programs.
1 = none
2 = the „GEM-Host“
3 = the line computer (LCU)
Process State Model
1002011 SV U1 PROCESSSTATE.
The current Process State.
0 = Machine Initialization
1 = Single Function
2 = Processing
1002012 SV U1 PREVIOUSPROCESSSTATE.
The Process State in effect before the most recent
transition to the current Process State.
0 = Machine initialization
1 = Single Function
2 = Processing
Alarm Management
1002013 SV U4 ALARMID.
The ALID of the most recent Alarm transition.
1002014 SV U1 ALARMSTATE.
The Alarm State now in effect for the most recently
transitioned alarm.
0 = Alarm transitioned OFF
1 = Alarm transitioned ON
1002015 SV U4 ALARMSERIAL.
The sequence number of the most recent alarm
change (going on or going off). This number starts at
zero at power-up and increments by one for each
alarm transition which occurs.
1002016 DV A[0-40] ALARMTEXT.

GEM for SIPLACE V5.01
Page 160 of 252 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
The Alarm Text (ALTX) for the most recently
transitioned Alarm.
1002017 DV B[1] ALARMSEVERITYCODE.
The Severity Code (ALCD low-order 7 bits) for the
most recently transitioned alarm.
1002018 EC U1 CONFIGALARMS.
An EC which controls which Alarm Report message
this Equipment will send.
0 = S5F1
1 = S5F71
2 = S5F73
1002019 EC U1 WBITS5.
An EC which controls the W-Bit setting used when
sending Alarm Reports (S5F1, S5F71, or S5F73).
0 = W-Bit not set
1 = W-Bit set
1002020 SV L ALARMSENABLED.
A list of all Alarms which are currently enabled.
Format as follows:
/
8$/,'!
!
1002021 SV L ALARMSSET.
A list of all Alarms which are currently in the SET (on)
state. Format as follows:
/
8$/,'!
!
Time and date
1002022 SV A CLOCK.
The Equipment's current Date and Time in the
following format: YYYYMMDDhhmmsscc.
YYYY = year
MM = month
DD = day
hh = hours
mm = minutes
ss = seconds