00191134-03.pdf - 第133页
GEM for SIPLACE V5.01 ©Siemens AG, all rights r eserved page 133 of 252 (TXLSPHQW5HSRUWV $QQRWDWHG Step SECS Mess age De scription 1. The Equipm ent recognizes that an event has occurr ed. The Host has enabled r…

GEM for SIPLACE V5.01
Page 132 of 252 ©Siemens AG, all rights reserved
(TXLSPHQW5HSRUWV(YHQW
Step SECS Message Description
1. The Equipment recognizes that an event has
occurred. The Host has enabled reporting for
the CEID, and possibly has defined one or more
Reports and linked them to the CEID. The
Equipment Constant RpType is set to „False“,
requesting normal reports.
2. H <- E S6F5 W Inquire. If S6F13 will be multi-block, the
Equipment first sends this Inquire to request
permission. If S6F11 is single-block, skip this
and the next step.
3. H -> E S6F6 Grant. The Host grants permission to send
multi-block event report. If GRANT6 is non-zero,
this scenario fails here, and the event data is
discarded.
4. H <- E S6F11 W The Equipment sends Event reports for the
CEID that occurred
5. H -> E S6F12 The Host acknowledges the report.

GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 133 of 252
(TXLSPHQW5HSRUWV $QQRWDWHG
Step SECS Message Description
1. The Equipment recognizes that an event has
occurred. The Host has enabled reporting for
the CEID, and possibly has defined one or more
Reports and linked them to the CEID. The
Equipment Constant RpType is set to „True“,
requesting Annotated reports.
2. H <- E S6F5 W Inquire. If S6F13 will be multi-block, the
Equipment first sends this Inquire to request
permission. If S6F13 is single-block, skip this
and the next step.
3. H -> E S6F6 Grant. The Host grants permission to send
multi-block event report. If GRANT6 is non-zero,
this scenario fails here, and the event data is
discarded.
4. H <- E S6F13 W The Equipment sends annotated event reports
for the CEID that occurred.
5. H -> E S6F14 The Host acknowledges the report.
1RWH In all other scenarios in which event reports occur, the Events or Annotated Events
are shown in abbreviated form (S6F11/S6F12 only). The complete Event Report
Scenarios are shown here.

GEM for SIPLACE V5.01
Page 134 of 252 ©Siemens AG, all rights reserved
+RVW,QLWLDWHV7UDFH
Step SECS Message Description
1. H -> E S2F23 W The Host initiates a trace.
2. H <- E S2F24 The Equipment acknowledges the trace request.
If the data in S2F23 is not valid, the
acknowledge code in this message is non-zero
and the scenario ends. Otherwise, the following
steps are done „TOTSMP“ times, where
TOTSMP is the total number of samples to be
done.
3. The Equipment waits „DSPER“ (data sample
period). While waiting, the Equipment continues
to operate normally, responding to any SECS
messages that may be received, etc. After the
wait is finished, the values of the variable(s) to
be traced are obtained and saved. If „REPGSZ“
samples have been saved, or if this is the last
sample, do the following steps.
4. H <- E S6F1 W The Equipment sends trace data.
5. H -> E S6F2 If the S6F1 has its W-bit set to 1, the Host
acknowledges the trace data.
6. If this is the last sample, the Equipment
terminates this trace and the scenario ends.
Otherwise, go back to the beginning of step 3.