00191134-03.pdf - 第179页

GEM for SIPLACE V5.01 ©Siemens AG, all rights r eserved page 179 of 252 9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ preceding st ation is active. Bit 2: If bit is set, the Interf ace signal "Perm ission&quot…

100%1 / 245
GEM for SIPLACE V5.01
Page 178 of 252 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
Bit 3: If bit is set, the proximity switch of the
adjustment width is switched.
Bit 4: If bit is set, the adjustment width is at the
limit switch.
Bit 5: If bit is set, the proximity switch of the
stopper is switched.
Bit 6: If bit is set, the software switch high voltage
is off.
Bit 7: If bit is set, the ceramic substrate centering
is open.
A value of -1 indicates an error
2012002 SV U1 INPUTPORTBYTE2
Bit 0: If bit is set, high voltage is on.
Bit 1: If bit is set, the emergency stop button is
down.
Bit 2: If bit is set, the protective covers are open.
Bit 3: If bit is set, the start button was actuated.
Bit 4: If bit is set, the stop button was actuated.
Bit 5: If bit is set, the key switch is not set.
Bit 6: If bit is set, the compress air unit is active.
Bit 7: If bit is set, the axis operation voltage is
active.
A value of -1 indicates an error
2012003 SV U1 INPUTPORTBYTE3
Bit 0: If bit is set, the gantry crash sensor was set
Bit 1: If bit is set, the gantry proximity sensor was
set.
Bit 2: If bit is set, the open proximity switch of the
nozzle changer of gantry 1 is switched.
Bit 3: If bit is set, the close proximity switch of the
nozzle changer of gantry 1 is switched.
Bit 4: If bit is set, the open proximity switch of the
nozzle changer of gantry 2 is switched.
Bit 5: If bit is set, the close proximity switch of the
nozzle changer of gantry 2 is switched.
Bit 6: If bit is set, the center conveyer sensor is
covered.
Bit 7: If bit is set, the center conveyer sensor of
parallel conveyor is covered. A value of -1
indicates an error
2012004 SV U1 INPUTPORTBYTE4
Bit 0: If bit is set, the Interface signal "Request"
to the preceding station is active.
Bit 1: If bit is set, the Interface signal "Sent" to the
GEM for SIPLACE V5.01
©Siemens AG, all rights reserved page 179 of 252
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
preceding station is active.
Bit 2: If bit is set, the Interface signal
"Permission" to the following station is
active.
Bit 3: If bit is set, the Interface signal "Received"
to the following station is active.
Bit 4: If bit is set, the input conveyor sensor is
covered.
Bit 5: If bit is set, the input conveyor sensor of the
parallel conveyer is covered.
Bit 6: If bit is set, the output conveyor sensor is
covered.
Bit 7: If bit is set, the output conveyor sensor of
the parallel conveyor is covered.
A value of -1 indicates an error
2012005 SV U1 INPUTPORTBYTE5
Bit 0: If bit is set, the upper proximity switch of the
lifting table of the second transport track is
not switched.
Bit 1: If bit is set, the lower proximity switch of the
lifting table of the second transport track is
not switched.
Bit 2: Not used.
Bit 3: If bit is set, the proximity switch of the
adjustment width of the second transport
track is switched.
Bit 4: If bit is set, the adjustment width of the
second transport track is at the limit switch.
Bit 5: Not used.
Bit 6: Not used.
Bit 7: If bit is set, the ceramic substrate centering
of the second transport track is open.
A value of -1 indicates an error
2012006 SV U1 INPUTPORTBYTE6
Bit 0: If bit is set, the Interface signal "Request"
to the preceding station of the second
transport track is active.
Bit 1: If bit is set, the Interface signal "Sent" to the
preceding station of the second transport
track is active.
Bit 2: If bit is set, the Interface signal
"Permission" to the following station is
active.
Bit 3: If bit is set, the Interface signal "Received"
to the following station of the second
transport track is active.
GEM for SIPLACE V5.01
Page 180 of 252 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
Bit 4: Not used.
Bit 5: Not used.
Bit 6: Not used.
Bit 7: Not used.
A value of -1 indicates an error
2012007 SV U4 OUTPUTPORTBYTE1
Bit 0: If bit is set, lifting table is moving up.
Bit 1: If bit is set, lifting table is moving down.
Bit 2: If bit is set, the nozzle changer of gantry 1
will be opened.
Bit 3: If bit is set, the nozzle changer of gantry 2
will be opened.
Bit 4: Bit to switch the compress air unit.
Bit 5: If bit is set, the stopper of the twin conveyer
will extend.
Bit 6: If bit is set, the stopper will extend.
Bit 7: Operates the ceramic substrate centering.
A value of -1 indicates an error
2012008 SV U1 OUTPUTPORTBYTE2
Bit 0: If bit is set, the right main malfunction
indicator illuminates.
Bit 1: If bit is set, the green light of the main
malfunction indicator illuminates.
Bit 2: If bit is set, the left main malfunction
indicator illuminates.
Bit 3: If bit is set, the barcode of the parallel
conveyer will be triggered.
Bit 4: If bit is set, the monitor of the ICOS will be
activated.
Bit 4/5: If bit 4 and 5 are set, the monitor of M44 will
be activated.
Bit 6: If bit is set, the barcode will be triggered.
Bit 7: If bit is set, the operation voltage will be
switched on.
A value of -1 indicates an error
2012009 SV U1 OUTPUTPORTBYTE3
Bit 0: Free for a second conveyor motor.
Bit 1: Free for a second conveyor motor.
Bit 2: If bit is set, the motor of the center
conveyor is in slow mode.
Bit 3: If bit is set, the motor of the center
conveyor is in fast mode.
Bit 4: If bit is set, the motor of the output conveyor