00197443-02_IM_707_1_DE_EN.pdf - 第21页

Station S oftware 70 7.1 / Ins tallation Man ual Ausgabe 05/2014 E dition 21 Name SIMAT IC Box PC 827C CPU / cloc k frequen cy Intel(R) Core( TM) i3 / 2 . 13 GHz R AM 2 GB Harddisk Yes Extern al DVD d rive Yes Intern al …

100%1 / 120
Station Software 707.1 / Installation Manual Ausgabe 05/2014 Edition
20
4.2.2 Machine/Vision Computer (in One-Computer Operation)
Name SIMATIC Box PC 627B
CPU / clock frequency Core 2 Duo T7400 / 2.16 GHz
RAM 1 GB (SX1/2 / DX1/2) / 2 GB (DX4)
Harddisk Yes
External DVD drive Yes
Internal DVD drive No
Serial interfaces 1
USB interfaces and external USB hub Yes
Network 2x 100 MBit
A24 Hotlink cards Yes (DX4) / No (SX1/2 / DX1/2)
Table 4-6: Machine/Vision computer hardware SIPLACE SX1/SX2 (V2) and DX-series
Name SIMATIC Box PC 627C
CPU / clock frequency Intel(R) Celeron(R) P4505 / 1.87 GHz
RAM 1 GB
Harddisk Yes
External DVD drive Yes
Internal DVD drive No
Serial interfaces 1
USB interfaces and external USB hub Yes
Network 2x 100 MBit
Table 4-7: Machine/Vision computer hardware SIPLACE SX1/2 (V2), DX-series, X-series S,
X4 S micron and X4i S micron
Name SIMATIC Box PC 827B
CPU / clock frequency Core 2 Duo T7400 / 2.16 GHz
RAM 2 GB
Harddisk Yes
External DVD drive No
Internal DVD drive No
Serial interfaces 1
USB interfaces Yes
External USB hub No
Network 2x 100 MBit
Table 4-8: Machine/Vision computer hardware SIPLACE X-series and SX4
Station Software 707.1 / Installation Manual Ausgabe 05/2014 Edition
21
Name SIMATIC Box PC 827C
CPU / clock frequency Intel(R) Core(TM) i3 / 2.13 GHz
RAM 2 GB
Harddisk Yes
External DVD drive Yes
Internal DVD drive No
Serial interfaces 1
USB interfaces and external USB hub Yes
Network 2x 100 MBit
Table 4-9: Machine/Vision computer hardware SIPLACE X-series, X-series S, X4 S micron, X4i S micron
and CA-series
Station Software 707.1 / Installation Manual Ausgabe 05/2014 Edition
22
4.3 Network Configuration
Machine
computer
Vision computer
10Base-T
or 100Base-T
cross-over cable
100Base-T
cross-over cable
Private network between
machine computer and Vision
computer
SIPLACE LAN
SIPLACE Pro
Twisted pair TP
(100 Mbit/s)
Twisted pair TP
(10 or 100 Mbit/s)
Figure 4-1: Network connections between the machine and SIPLACE Pro
In two-computer operation a separate private network (100 Mbit/s) is set up between the machine
computer and the Vision computer via a subnet mask.
Fixed IP addresses for the machine computer and the Vision computer can thus be assigned for all
SIPLACE machines. These IP addresses are not known outside the private network, for instance in
the SIPLACE LAN.
These IP addresses need not be further configured by the operator while the station software is
being installed.