Station Software 707.1 / Installation Manual Ausgabe 05/2014 Edition
49
When you have selected all table configurations the following window is displayed, in which you
confirm the Auto-configuration.
Figure 7-9: Confirming Auto-configuration for SX1/SX2
Click the Confirm changes and continue startup button to confirm the Auto-configuration.
If the Coplan computer has been installed, you will additionally have to confirm or reject the 3-D
Coplan sensor.
7.4 SX+ Placement Machine
If the SX+ placement machine is to be used without gantries, this has to be configured in the Auto-
configuration after the machine has been booted.
For this, select Ignore gantries at the processing area in the machine configuration dialog.
Station Software 707.1 / Installation Manual Ausgabe 05/2014 Edition
50
7.5 SX4 Placement Machine
When the SX4 placement machine is booted for the first time you have to select the SX4
Flexible entry for Machine frame manually in the Auto-configuration, if there are tables in
outer position in processing area 2, as this is not detected automatically via sensors.
Tables in outer position are used when stationary cameras are in use.
Otherwise you select the SX4 High Speed entry.
7.6 DX-Series Placement Machines
When the DX placement machines are booted for the first time you have to select the following
options manually:
For C&P12 placement head: height position (altitude)
Lamp indicators (two-colored or three-colored)
Table position:
inner 60 tracks
outer 60 tracks
outer with 30 tracks + free location for tray or WPC
Confirm/reject 3-D Coplan sensor
7.7 Checking/Updating the Embedded Software
If the correct eSW versions are not available on the machine, the machine boot gets interrupted.
In this case, perform an eSW download.
Start an overall reference run for the machine.
7.8 Storage Location of the Machine Files (Calibration Data etc.)
The machine-specific configuration, measurement and parameter data is stored in XML files under
C:\Sirio\Work\Individual. These XML files contain all the calibration data.
Station Software 707.1 / Installation Manual Ausgabe 05/2014 Edition
51
7.9 Necessary Calibration Steps
After upgrading from station software 70x and first booting of the station software, some calibration
steps are required.
Requirements:
The eSW versions have been updated.
The reference run has been sucessfully performed.
A calibration nozzle (1235) has to be available on every C&P20A placement head at
segment 1.
Figure 7-10: Required calibration steps
Select the calibration steps that are highlighted in the figure and click on Next.
Select all possible components in the following input masks (all conveyor lanes, all gantries, all
nozzle changers).