141-400-57-probestationaccessoriescatalog.pdf_-_141-400-probestationaccessoriescatalog_1.pdf.pdf - 第89页
PN 141-400 www.formfactor.com Positioners and Posit ioner Accesso ries • 73 Revision 57, February, 2023 Probe Station A ccessories • Mi crometer set planarity ad jus tment • EMI gr ounding strap • I ndustry standard RF p…

PN 141-400 www.formfactor.com Positioners and Positioner Accessories • 72
Revision 57, February, 2023 Probe Station Accessories
• RPP304-W-SU-AI
RPP304-EW/NS-EL-AI
Features
• Precision 4-axis probe
positioner for RF/microwave
probes
• Optimized for Elite
MicroChamber platform
• Rigid design for optimal probe
placement
• One-click positioner qu ick
release control enables fast setup and effortless gross positioning
of RF probes
• Smooth glide micrometer controls enable accurate probe
placement
• Multi position RF cable clamp and offset probe mounting arm
optimize RF cable connection
• Micrometer set planarity ad justment
• EMI grounding strap
• Industry standard RF probe mount
Specifications
• Feature resolution: <1 μm (0.04 mils)
• Travel range:
– X/Y: 12 mm (0.47 in)
– Z: 12 mm (0.47 in) (z-axis contr ol: cw=down, ccw=up)
• Micrometer screws: 1000 μm ( 39.4 mils) pitch (25 TPI)
• Micrometer set planarity ad just: ±5°
• Gross X travel: 26 mm ( 1 in) with TopHat; 68 mm (2.7 in) with no
TopHat/insert
• 2-port probe tip separation
– With MicroChamber TopHat: 40 mm (1.6 in)
– Without MicroChamber TopHat: 93 mm (3.7 i n)
• Probe mount interface: 3 hole FormFactor standard d esign, with
locating pin
Configurations
• Use on platen right/left location as East/West positioner (4-port)
• Use on platen top/bottom loca tion as North/South positioners (4-
port)
Compatibility
• Elite300
Ordering Information
• RPP304-NS-EL-AI
• RPP304-EW-EL-AI
• RPP304-W-EL-AI
RPP304-EW/NS/W-67 — Positioner (North/South)
Features
• Enables probes in north/south
position
• Supplied with Chamber/EMI
seal
Specifications
• Compatible with 67 GHz and
lower RF probes, or DCQ
probes
• Feature resolution: <1 μm (0.04 mils)
• Travel range:
– X/Y: 12 mm (0.47 in)
– Z: 12 mm (0.47 in) (z-axis control: cw=down, ccw=up)
• Micrometer screws: 1000 μm (39.4 mils) pitch (25 TPI)
• Micrometer set planarity adjust: ±5°
• Probe mount interface: 3 hole FormFactor standard design, with
locating pin
Compatibility
• CM300xi, SUMMIT200, TESLA200, Elite300
Ordering Information
• RPP304-EW-67
• RPP304-W-67
• RPP304-NS-67
RPP305-EW/NS-EL/SU-AI
Features
• Used for high-performance
RF, m ulti-contact/mixed signal
probing, high-performance
wafer-level reliability probing,
and single-ended broadband/
mm-Wave, THz, source/load-
pull, RF noise probing
• Used with Infinity / ACP / |Z| Probe / T-Wave high performance RF
probes
• Precision 4 axis pr obe positioner for RF/microwave probes
• Optimized for Elite 300 /Summit 12000-B station platform
• Ultra rigid design for best probe placement
• New one-click positioner quick release control allows fast setup
and e ffortless gross positioning of RF probes
• Smooth glide micrometer controls enable accurate probe
placement
• Best probe-to-probe separation
• Multi position RF cable clamp and offset probe mounting arm for
optimized RF cable connection

PN 141-400 www.formfactor.com Positioners and Positioner Accessories • 73
Revision 57, February, 2023 Probe Station Accessories
• Micrometer set planarity ad justment
• EMI grounding strap
• Industry standard RF probe mount
Specifications
• Feature resolution: <1 μm (0.04 mils)
• Travel range:
– X/Y: 25 mm (1 in),
– Z: 10 mm (0.4 in) (z-axis control: cw=down, ccw=up)
• Micrometer set planarity ad just: ±5°
• Micrometer screws: 500μm pitch (50 TPI)
• 2-port probe tip separation
– With TopHat: 40 mm (1.6 in)
– Without TopHat: 93 mm (3.7 in)
• Mount: bolt-down
• Footprint (W x D): 1 24 x 124 mm (4.9 x 4.9 in)
Configurations
• Use on platen right/left location as East/West positioner (4-port)
• Use on platen top/bottom loca tion as North/South positioners
(4-port)
Compatibility
Ordering Information
RPP305-EW/NS-CM-AI
Features
• Use d for high-performance
RF, multi-contact/mixed signal
probing, high-performance
wafer-level reliability probing,
and single-ended broadband/
mm-Wave, THz, s ource/load-
pull, RF noise probing
• Use d with Infinity / ACP / |Z|
Probe / T-Wave high
performance RF probes
• Precision 4 axis probe positioner for RF/microwave probes
• Optimized for CM300xi station platform
• Ultra rigid design for best probe placement
• New one-click positioner quick release control enables fast setup
and e ffortless gross positioning of RF probes
• Smooth glide micrometer controls for accurate probe placement
• Best probe-to-probe separation
• Multi position RF cable clamp and offset probe mounting arm for
optimized RF cable connection
• Micrometer set planarity adjustment
• EMI grounding strap
• Industry standard RF probe mount
Specifications
• Feature resolution: <1 μm (0.04 mils)
• Travel range:
– X/Y: 25 mm (1 in),
– Z: 10 mm (0.4 in) (z-axis control: cw=down, ccw=up)
• Micrometer set planarity adjust: ±5°
• Micrometer screws: 500μm pitch (50 TPI)
• 2-port probe tip separation
– With TopHat: 40 mm (1.6 in)
– Without TopHat: 93 mm (3.7 in)
• Mount: bolt-down
• Footprint (W x D): 124 x 124 mm (4 .9 x 4.9 in)
• Use on platen right/left location as East/West positioner (4-port)
• Use on platen top/bottom location as North/South positioners
(4-port)
Compatibility
• CM300xi with Top Ha t, Elite 300
Ordering Information:
• RPP305-EW-CM-AI
• RPP305-NS-CM-AI
RPP305-EW/NS-CMC-AI — High Performance RF Probe
Positio ner 50 TPI Bolt Down East-West or North-South
Features
• Used for high-
performance RF, multi-
contact/mixed signal
probing, high-
performance wafer-
level reliability probing,
and single-ended
broadband/ mm-
Wave, THz, source/load-pull, RF noise probing
• Used with Infinity / ACP / |Z| Probe / T-Wave high performance RF
probes
• Precision 4 axis pr obe positioner for RF/microwave probes
• Optimized for CM300xi station platform
• Ultra rigid design for best probe placement
Open Platforms +
EL Arms
Open Platforms +
SU Arms
Elite 300 Summit 12000
Tesla200
Elite 300 Summit 12000
RPP305-NS-EL-AI
RPP305-EW-EL-AI
RPP305-NS-SU-AI
RPP305-EW-SU-AI
East-West

PN 141-400 www.formfactor.com Positioners and Positioner Accessories • 74
Revision 57, February, 2023 Probe Station Accessories
• New one-click positioner quick
release control allows fast
setup and effortless gross
positioning of RF probes
• Smooth glide micrometer
controls for accurate probe
placement
• Best probe-to-probe separation
• Multi position RF cable clamp
and o ffset probe mounting arm
for optimized RF cable
connection
• Micrometer set planarity ad justment
• Industry standard RF probe mount
Specifications
• Feature resolution: <1 μm (0.04 mils)
• Travel range:
– X/Y: 25 mm (1 in),
– Z: 10 mm (0.4 in) (z-axis control: cw=down, ccw=up)
• Micrometer set planarity ad just: ±5°
• Micrometer screws: 500μm pitch (50 TPI)
• 2-port probe tip separation
– With TopHat: 40 mm (1.6 in)
– Without TopHat: 93 mm (3.7 in)
• Mount: bolt-down
• Footprint (W x D): 1 24 x 124 mm (4.9 x 4.9 in)
Configurations
• Use on platen right/left location as East/West positioner (4-port)
• Use on platen top/bottom loca tion as North/South positioners
(4-port)
Compatibility
• CM300xi with top chambers
Ordering Information
• RPP305-NS-CMC-AI
• RPP305-EW-CMC-AI
RPP305-EW/NS-HT-AI
Features
• Use d for high-performance
RF, multi-contact/mixed signal
probing, high-performance
wafer-level reliability probing,
and single-ended broadband/
mm-Wave, THz, s ource/load-
pull, RF noise probing
• Used with Infinity / ACP / |Z| Probe / T-Wave high performance RF
probes
• Precision 4-axis probe positioner for RF/microwave probes
• High temperature stability
• Recommended for testing at high temperatures or multiple
temperatures
• Optimized for CM300xi station platform
• Ultra rigid design for best probe placement
• New one-click positioner quick release control enables fast s etup
and e ffortless gross positioning of RF probes
• Smooth glide micrometer controls for accurate probe placement
• Best probe-to-probe separation
• Multi position RF cable clamp and offset probe mounting arm for
optimized RF cable connection
• Micrometer set planarity adjustment
• EMI grounding strap
• Industry standard RF probe mount
Specifications
• Feature resolution: <1 μm (0.04 mils)
• Travel range:
– X/Y: 25 mm (1 in),
– Z: 10 mm (0.4 in) (z-axis control: cw=down, ccw=up)
• Micrometer set planarity adjust: ±5°
• Micrometer screws: 500μm pitch (50 TPI)
• 2-port probe tip separation
– With TopHat: 40 mm (1.6 in)
– Without TopHat: 93 mm (3.7 in)
• Mount: bolt-down
• Footprint (W x D): 124 x 124 mm (4 .9 x 4.9 in)
• Use on platen right/left location as East/West positioner (4-port)
• Use on platen top/bottom location as North/South positioners
(4-port)
Compatibility
• CM300xi with Top Ha t, Elite 300
Ordering Information
• RPP305-EW-HT-AI
• RPP305-NS-HT-AI
North-South