141-400-57-probestationaccessoriescatalog.pdf_-_141-400-probestationaccessoriescatalog_1.pdf.pdf - 第93页

PN 141-400 www.formfactor.com Positioners and Posit ioner Accesso ries • 77 Revision 57, February, 2023 Probe Station A ccessories RPP 504 - NS-6 7 Feat ur es • Use d for autonomous RF probing up to 67 GHz • Use d with I…

100%1 / 169
PN 141-400 www.formfactor.com Positioners and Positioner Accessories 76
Revision 57, February, 2023 Probe Station Accessories
RPP404 / RPP404-W
Features
Use d for high-performance
RF, multi-contact/mixed signal
probing, high-performance
wafer-level reliability probing,
and single-ended broadband/
mm-Wave, THz, s ource/load-
pull, RF noise probing
Use d with Infinity / ACP / |Z|
Probe / T-Wave high performance RF probes
Version for East and West
Specifications
Compatible with RFA probe arms
Feature resolution: <1 μm (0.04 mils)
Travel range: 12 mm (0.47 in) in X, Y, and Z (z-axis control:
cw=down, ccw=up)
Micrometer screws: 1000 μm ( 39.4 mils) pitch (25 TPI)
Mount: bolt-down (large base)
Footprint (WxD): 124 x 149.5 mm (4.9 x 5.9 in)
Configuration
Use adapter (174-889) for mounting to Summit 11 000/12000
stations
Use adapter (174-973) for mounting to EPS stations
Compatibility
CM300xi, SUMMIT200, Elite
EPS15 0, EPS200, Summit 11 000/12000 with d edicated ada pter
191-446 Micrometer Screw for RPP404 X-axis
Features
Digital micrometer screw
for RPP404 X- axis to
support precise multiline
TRL calibrations
Replaces the manual X-
axis micrometer with a
micrometer with digital
LCD readout
For RPP404 and RPP304 positioners
Preset, inch/mm conversion
Specifications
Res olution: 0.001mm (.00005 in)
Repeatability: < +/- 0.6 µm (0.24 mils)
Accuracy: < +/- 1 µm (0.04 mils) (within +/- 2 mm travel range)
Compatibility
For RPP404 and RPP304 positioners
Can be mounted on all axes
RPP504
Features
Used for autonomous RF,
multi-contact/mixed signal
probing, high-performance
wafer-level reliability probing,
and single-ended broadband/
mm-Wave, THz, source/load-
pull, RF noise probing
Used with Infinity / ACP / |Z|
Probe / T-Wave high
performance RF probes
Universal version for East and West
Specifications
Compatible with RFA probe arms
Feature resolution: <1 μm (0.04 mils)
Travel range: 12 mm (0.47 in) in X, Y, and Z (z-axis control:
cw=down, ccw=up)
Minimum step size 0.3 µm / 0.1 µm resol ution
Mount: bolt-down (large base)
Footprint (WxD): 124 x 149.5 mm (4.9 x 5.9 in)
Configuration
Requires MPX controller (178-511 for up to 4 positioners, 181 -170
for up to 2 positioners, 183-111 for single positioner)
Requires station adapter kit (178-517 for CM300xi, 183-825 for
SUMMIT200, 178-920 for EPS)
For use with ECX box on 12KB/E300, one interface 174-544 per
positioner required
Use adapter (174-973) for mounting to EPS stations
Use adapter (174-889) for mounting to Summit 11000/12000
stations
Compatibility
CM300xi, SUMMIT200, El ite
EPS150, EPS200, Summi t 11000/12000 with dedicated adapter
PN 141-400 www.formfactor.com Positioners and Positioner Accessories 77
Revision 57, February, 2023 Probe Station Accessories
RPP504-NS-67
Features
Use d for autonomous
RF probing up to 67
GHz
Use d with Infinity / ACP
/ |Z| Probe / T-Wave
high performance RF
probes
Version for North and
South
Specifications
Feature resolution: <1 μm (0.04 mils)
Travel range: 12 mm (0.47 in) in X, Y, and Z (z-axis control:
cw=down, ccw=up)
Minimum step size 0.3 µm / 0.1 µm resolution
Mount: bolt-down (large base)
Footprint (WxD): 124 x 149.5 mm (4.9 x 5.9 in)
Configuration
Requires MPX controller (178-511 for up to 4 positioners, 181-170
for up t o 2 positioners, 1 83-111 for single positioner)
Requires station adapter kit (178-517 for CM300xi, 183-825 for
SUMMIT200, 178 -920 for EPS)
For use with ECX box on 12KB/E300, one interface 174-544 per
positioner required
Use adapter (174-973) for mounting to EPS stations
Use adapter (174-889) for mounting to Summit 11 000/12000
stations
Compatibility
CM300xi, SUMMIT200, Elite
EPS15 0, EPS200, Summit 11 000/12000 with d edicated ada pter
PN 141-400 www.formfactor.com Positioners and Positioner Accessories 78
Revision 57, February, 2023 Probe Station Accessories
RF and Microwave Cables
Infinity probe shown with TopHat
incompatible cable (left)
Infinity probe with Top Hat
compatible cable (right) .
An extended ferrule shorts
the coax shield to the EMI
gasketed TopHat for local
ground reference.
Cables for unshielded environments
GORE P/N Junkosha P/ N Freq Style Length Probe station
101-162-B
180-801 40 GHz vertical probe ~120 cm (48 in) EPS with SlimVue
103-202-B
180-805 50 GHz vertical probe ~120 cm (48 in) EPS with SlimVue
124-084-B 180-800 40 GHz angled probe ~120 cm (48 in) EPS with SMZ168
124-085-B 180-804 50 GHz angled probe ~120 cm (48 in) EPS with SMZ168
124-605-B
180-809 67 GHz vertical probe ~90 cm (3 6 in) EPS with SlimVue*
124-606-B 180-808 67 GHz angled probe ~90 cm (36 in) EPS with SMZ168*
132-458 180-812 110 GHz angled probe 18 cm (7.1 in) EPS with SlimVue*
* Rear mounted instrument rack recommended.
Item on limited supply. If possible, convert to alternative from Junkosha.
Item is obsolete, listed for reference only.
Cables for shielded environments with TopHat
GORE P/N Junkosha P/N Freq Style Length Probe station
132-420
180-803 40 GHz vertical probe ~120 cm (48 in)
CM300, Elite, SUMMIT200, Summit 11000/12000
132-421
180-807 50 GHz vertical probe ~120 cm (48 in)
CM300, Elite, SUMMIT200, Summit 11000/12000
132-422
180-811 67 GHz vertical probe ~90 cm (36 in)
CM300, Elite, SUMMIT200, Summit 11000/12000*
132-423
180-802 40 GHz angled probe ~120 cm (48 in)
CM300, Elite, SUMMIT200, Summit 11000/12000
132-424
180-806 50 GHz angled probe ~120 cm (48 in)
CM300, Elite, SUMMIT200, Summit 11000/12000
132-425‡ 180-810 67 GHz angled probe ~90 cm (36 in)
CM300, Elite, SUMMIT200, Summit 11000/12000*
132-458 180-812 110 GHz angled probe 18 cm (7.1 in)
Summit 11000/12000 single port*
147-316 180-813 110 GHz angled probe 24 cm (9.4 in)
CM300, Elite, Summit 110 00/12000*,**
178-383 110 GHz angled probe 10 cm (3.9 in)
EPS150, EPS200, SUMMIT200, Elite, and CM300xi*
178-387 110 GHz angled probe 13 cm (5.1 in)
EPS150, EPS200, SUMMIT200, Elite, and CM300xi*
* Rear mounted instrument rack recommended.
** For Summit 11000/12000 multiport set-up.
Item on limited supply. If possible, convert to alternative from Junkosha.
Item is o bsolete, listed for reference only.