00192791-02.pdf - 第61页

User Manual 2 Ceramic Substrate Centering Unit Software Version S R.502.xx 01/01 Issue 2.8 Configuration Ceramic Subs trate Centering 61 Å The followi ng option s are avai lable in the "E dit" wind ow . CAUTION…

100%1 / 66
2 Ceramic Substrate Centering Unit User Manual SIPLACE HS-50
2.8 Configuration Ceramic Substrate Centering Software Version SR.502.xx 01/01 Issue
60
 $FWLYDWLRQDQG&RQILJXUDWLRQRI&HUDPLF6 XEV WUDW H&HQWHULQJ
Å Start the SITEST program.
Å Select "Settings" in the menu bar.
Å In the menu "Machine configuration" select the option "Ceramic substrate centering
" (= pro-
cessing range 1 and 2) -> "Edit".
The "Edit" window is indicated, as follows:
User Manual 2 Ceramic Substrate Centering Unit
Software Version SR.502.xx 01/01 Issue 2.8 Configuration Ceramic Substrate Centering
61
Å The following options are available in the "Edit" window.
CAUTION
The options "Additional PCB camera illumination" or "None" are not relevant for ceramic substrate
centering.
However, if you do select one of these options, you must first DEinstall the entire mechanical ce-
ramic substrate centering unit and restore PCB clamping on the pertinent conveyor as described
in the Service Manual.
If you fail to do so, the next PCB or the mechanical substrate centering unit may be damaged. 2
Å If you want to use the mechanical ceramic substrate centering in combination with the sub-
strate position recognition via PCB camera (normal illumination) or PCB camera multicolor, se-
lect:
0HFKDQLFDOFHQWHULQJVW DWLRQ-> "Accept".
Option in the "Edit" window Explanation
None Normal transport of PCBs with PCB clamping and PCB
position recognition via PCB camera (normal illumination)
or with PCB camera multicolor.
The hardware of the mechanical ceramic substrate center-
ing has to be removed and the conveyor must be equipped
to clamp PCBs.
Mechanical centering station Mechanical ceramic substrate centering AND substrate
position recognition via PCB camera (normal illumination)
or optinonal PCB camera multicolor.
Additional PCB camera illumina-
tion
No mechanical centering,
ONLY position recognition via optional oblique illumination
(annular illumination).
-> Oblique illumination is ONLY possible for both convey-
ors.
CAUTION:
For this purpose, the hardware of the mechanical ceramic
substrate centering has to be removed and the conveyor
must be equipped to clamp PCBs.
Mechanical and oblique illumi-
nation
Mechanical substrate centering AND substrate position rec-
ognition illumination via optional oblique illumination of the
PCB camera.
-> Oblique illumination is ONLY possible for both convey-
ors.
2 Ceramic Substrate Centering Unit User Manual SIPLACE HS-50
2.8 Configuration Ceramic Substrate Centering Software Version SR.502.xx 01/01 Issue
62
Å If you want to use the mechanical ceramic substrate centering in combination with the sub-
strate position recognition via the optional oblique illumination, select:
0HFKDQLFDODQGREOLTXHLOOX PLQDWL RQ
-> "Accept".
Å If the machine only has a
VLQJOH
conveyor, exit the menu "Machine configuration" by pressing
"Accept".
In the following cases, a NOTE or error message is output on the screen:
A NOTE is output,
if you selected the SITEST menu option "None" or "Additional PCB camera illumination, i.e.,
a menu option WITHOUT the mechanical ceramic substrate centering unit, although the
hardware for mechanical ceramic substrate centering is still INSTALLED.
-> The NOTE text means that, prior to further work, the mechanical ceramic substrate cen-
tering unit in the pertinent conveyor must be removed and the plug-in connections on the
conversion board of the conveyor control must be unplugged. Otherwise the PCB and/or
the mechanical ceramic substrate centering unit (X-centering unit) may be damaged.
An ERROR message is then output,
if you selected the SITEST menu option "Mechanical centering station" or "Mechanical and
oblique illumination" i.e., a menu option WITH mechanical ceramic substrate centering, al-
though the hardware for the ceramic substrate centering is not - or is not completely in-
stalled.
-> The message means that the option is not installed in the pertinent conveyor or that, in
connection with, e.g., the option that was retrofitted, the relevant plug-in connection to the
conveyor control has not been made, is poor or was incorrectly allocated.
Å If a
GXDO
conveyor has been installed, your next step is to select, in the Edit menu:
"Ceramic substrate centering, conveyor
".
Configure the mechanical substrate centering unit in an analog manner to that described
above for Conveyor 1.
Note, however, for the possible combinations between Conveyor 1 and 2:
The combination "None" and "Mechanical centering station" is possible if the pertinent con-
veyor is appropriately equipped (with or without mechanical ceramic substrate centering
unit).
NOT possible is the combination of position recognition with oblique illumination in one con-
veyor and with normal illumination and/or with "None" in the other conveyor. If you select
this constellation, position recognition with oblique illumination is automatically accepted for
BOTH conveyors. In this case, the mechanical ceramic substrate centering unit must al-
ways be DEINSTALLED from both conveyors and the plug-in connections on the conver-
sion boards of the conveyor control must be unplugged.
Otherwise the PCB and/or the mechanical ceramic substrate centering unit (X-centering
unit) may be damaged.