3.10 Check the alignment of the encoder reader of the Y gantry
Whenever the encoder readers have been removed, the readers need to be realigned.
Requirements:
Machine is switched on.
Optical head is centered on the X position.
Figure 3-29: Position of the flexures and the optical head
Key:
1) Optical head
2) Flexures
Key:
1) Flexures
Figure 3-30: Flexures
1. Install the flexures (1) at the gantry.
Flexures
Without the flexures the gantry can be moved in slightly different positions. The flexures
ASM ProcessLens Single-lane 03/2020 Edition
34
Figure 3-31: Gantry Index ParallelTool
2. Start the Process "Gantry Index ParallelTool"
3. Press the Init button to initialize the gantry.
4. Press the "Start Gantry encoder TEST" button.
5. Slowly push the gantry backwards.
NOTICE
Test results
This needs to be done within 5 seconds after the button has been pushed. Otherwise the
6. Press the "Stop the Gantry Encoder" button.
7. Repeat this at least 10 x times.
8. The specified range is +/- 1000.
9. If any of the 10 X results differ from the specified range go back to adjust the brackets and
repeat the check.
Installed flexures
Installed flexures cause damage to the machine when in operation mode,
ASM ProcessLens Single-lane 03/2020 Edition
35
3.11 Check the alignment of the x, y and z encoder reader
Furthermore the alignment of the x, y and z readers need to be checked whenever the readers or
the scale bar has been changed.
Requirement:
Machine is switched on.
Figure 3-32: Diagnostic page
1. Go to the diagnostic page.
2. Click on the tab "Unit function".
3. Go to the section "Gantry".
4. Select the X button and click on the "Home" button.
5. Approach the same for the y and z readers.
3.12 Changing the Y scale bars
Key:
1) Y scale bar
2) Scale
Figure 3-33: Y scale bar
Requirement:
Machine is switched off.