1OM-1603-006_w.pdf - 第71页
1OM-1603 1-14 2. Name and Function of Each Section : Chap.1 1012-003 2.3.2 Light Tower The light tower indicates the condition of the machine with the lamps and buzzer sounds. Red Y ellow Green Buzzer Light T ower Light …

1OM-1603
1-13
2. Name and Function of Each Section : Chap.1
1012-004
•
Unlocking the Power Breaker
Remove the padlock from the lock lever of the power breaker.
Front Side of Machine
Power Breaker
Lock Lever
Padlock
Unlocking the Power Breaker
F1A9
•
Locking the Power Breaker
Lock the power breaker with the padlock when the machine is not to be used
for a long period of time.
Procedure
(1) Pull out the lock lever of the power breaker in Direction A (indicated in the
gure below).
(Be sure not to release your hand from the lock lever. Otherwise, the lock
lever will pull back in place.)
(2) Engage the shackle of the padlock through the lock slot and lock the crank.
A
(Unlocked) (Locked)
Lock Lever
F1A10

1OM-1603
1-14
2. Name and Function of Each Section : Chap.1
1012-003
2.3.2 Light Tower
The light tower indicates the condition of the machine with the lamps and buzzer
sounds.
Red
Yellow
Green
Buzzer
Light Tower
Light Tower F1A11
•
Lamp Colors (ON Mode)
The machine is factory-adjusted upon shipment.
Lamp Colors
(ON Mode)
Machine Condition
Red
Error (Operation Stopped)
Yellow
Component Shortage (Warning)
Green
Automatic Operation
When the machine is in the standby mode, this lamp
ickers.
T1A3
CAUTION
When the green lamp of the light tower is ON or ickering
(ON and OFF), it indicates that the static machine is in the
"Automatic" mode (standby mode).
•
Buzzer
Buzzer Machine Condition
Continuous Sound
Emergency Stop
Intermittent Sound
Error
T1A4
Note
The condition of the machine corresponding to the parameters specied for each
lamp color and buzzer sound can be changed in the "Machine Setup" window.

1OM-1603
1-15
2. Name and Function of Each Section : Chap.1
1012-004
2.3.3 Auxiliary Lamps
The auxiliary lamps are used to indicate in which block the machine status
(indicated by the tower lamp) is generated.
Auxiliary Lamps
F1A12
•
Lighting Condition of Lamps
Lighting Condition Machine Status (based on each block)
ON Normally Running or Under Operation
ON and OFF
(Flickering)
Error or Component Shortage
Note
When an error is not related to any block, all
auxiliary lamps icker.
OFF Stop Mode
T1A5
Note
When component shortage has occurred, replenish the component supply.