00191413-01.pdf - 第296页

9 Production Tools / Feeders User Manu al Line Computer UNIX 9.1 Feeder Editor Software Version 501.xx 01/99 Issue 9 - 12 9.1. 3.4 Command Area The comman ds are symboli zed by m eans of i cons. The y determ ine the mo d…

100%1 / 621
User Manual Line Computer UNIX 9 Production Tools / Feeders
Software Version 501.xx 01/99 Issue 9.1 Feeder Editor
9 - 11
9.1.3.3 Setting Area
The setting area contains buttons for the settings "Left side", "Line" and "Right side".
By clicking on the appropriate button it is possible to assign a given feeder, which is subsequently to be selected
from the selection field "Placeable feeders", either to a specific side, or without any restrictions.
NOTE
If the "Line" button is activated, this means that any subsequently defined allocations of feeders apply to the
feeder parts on both sides of the line on which they can be set up.
If a particular machine type or a feeder part of a particular machine type is selected, all buttons in the
setting area are deactivated so that the allocation only applies to the selected machine type or the
selected feeder part of the machine type.
Caution! When allocating package forms to waffle-pack trays, "Line" must be selected as the location.
Procedure for the allocation of a feeder to a package form on the left or right side:
Select the package form (see section 9.1.3.2).
Activate icon in the command area (see section 9.1.3.4).
Click on the Left side or Right side button.
All feeder parts on the left side or right side of the line are highlighted in green.
Click on feeder in the selection field "Placeable feeders".
The name of the selected feeder is displayed in the selection field "Feeder" followed by the letter
"L" or "R". This means that the current package form can be supplied by means of this feeder,
either from the left or right side.
Procedure for the allocation of a feeder to a package form on the machine type "SIPLACE80F", right
side of the machine:
Select the package form (see section 9.1.3.2).
Activate icon in the command area.
Click on feeder part on the right side of the machine type "SIPLACE80F" (see Fig. 9.1.2).
The feeder part is highlighted in green.
Click on feeder in the selection field "Placeable feeders".
This means that the feeder entered may be set up on the right feeder part of the machine type
"SIPLACE80F" only.
The name of the allocated feeder, the machine type and the machine side on which the feeder
can be set up are displayed in the selection field "Feeder".
Example: FD~S_G_8_EL S_SIP_80_F R
9 Production Tools / Feeders User Manual Line Computer UNIX
9.1 Feeder Editor Software Version 501.xx 01/99 Issue
9 - 12
9.1.3.4 Command Area
The commands are symbolized by means of icons. They determine the mode (selection mode, allocation mode
or deletion mode) in which the Feeder Editor is to operate.
NOTE
Upon opening, the Feeder Editor is initially in the selection mode.
- (Select)
When this icon is active (displayed in reverse video, with arrow pointing from the lower left to the upper
right), the editor is in the selection mode. It is possible to select machine types or individual elements
from the display area, and feeding units from the selection fields, by clicking the left mouse button.
Click on icon in the command area.
(The arrow in the icon now points to the upper right).
Click on machine element (feeder part) in the display area (see Fig. 9.1.2).
The selected element is highlighted in green.
In the selection field "Placeable feeders" all feeders or waffle-pack trays are displayed that can be
set up on the selected element.
NOTE
Double-clicking on an entry in the selection field "Placeable feeders" causes the window for
editing the feeder or waffle-pack tray data to be opened (see section 9.1.4).
- (Allocate)
When this icon is active, the editor is in the allocation mode.
Click on icon in the command area.
Click on, for example, the Line button in the setting area to allocate the subsequently selected
feeding unit without any restrictions (see section 9.1.3.3). All machine types are now highlighted
in green.
Select the feeder or waffle-pack tray from the selection field "Placeable feeders" .
The selected unit is displayed in the "Feeder" selection field.
NOTE
Further allocation possibilities are described in section 9.1.4.
Double-clicking on an entry in the selection field "Placeable feeders" causes the window for
editing the feeder of waffle-pack tray data to be opened (see section 9.1.4).
User Manual Line Computer UNIX 9 Production Tools / Feeders
Software Version 501.xx 01/99 Issue 9.1 Feeder Editor
9 - 13
- (Delete)
When this icon is active, the editor is in the deletion mode. In this mode it is possible to delete allocati-
ons and "customer-specific types" from the selection fields.
NOTE
In the selection field "Placeable feeders" only
created "customer-specific types" (see ) can be deleted.
If an attempt is made to delete a SIEMENS-defined type (feeder or waffle-pack tray), a
corresponding error message is displayed.
Click on icon in the command area.
Select the allocation to be deleted in the selection field "Feeder", or the entry of a customer-speci-
fic type from the selection field "Placeable feeders". The selected entry is deleted from the se-lec-
tion field.
NOTE
If the customer-specific type in the ".ri"-file is still being used (i.e. it is still allocated to other compon-
ents or package forms), a message contained in a dialog box appears to inform the operator of this
fact. If the operator deletes the customer-specific type nevertheless, all
allocations to the customer-
specific type will be lost.
9.1.4 Creating Allocations
This section explains the procedure to be followed for the creation of allocations, on the basis of examples "A"
and "B".
Example "A" describes the allocation of "Package form --> Feeder" and
example "B" describes the allocation of "Component --> Feeder".
Example "A" for package form "704"
Task:
1. Components with the package form "704" are to be set up in the customer-specific type "FM_PLCC" (waffle-
pack tray) on the waffle-pack tray carrier"FT~S_Typ_1", on all feeder parts of the line where the customer-
specific type "FM_PLCC" can be set up.
Steps to be performed:
1. Setting the Feeder Editor for editing package form "704"
Click on editing field "Package form", enter package form number 704 and complete the entry by
pressing RETURN.
The comment ("PLCC68") entered in the Package Form Editor is displayed in the "GF name" field.