14 Control / Cont rol Modules User Manual Line Computer UNIX 0.2 Job Control S oftware Version 501.xx 01/99 Issue 14 - 16 - Search ing In the se arch win dow dif ferent search criteria , e.g. fo r the name of the lin e o…

User Manual Line Computer UNIX 14 Control / Control Modules
Software Version 501.xx 01/99 Issue 0.2 Job Control
14 - 15
- Editing of Basic Optimization Data
● Click on the icon and subsequently the icon.
The FSB with the file selection of all configured lines opens.
● Successively select the line ".ak" and the subline ".va" by double-clicking.
● Click on Abort in the FSB.
The FSB closes, and the selected data are transferred to the appropriate editing fields.
NOTE
If a fixed setup is to be used for assembly, a setup ".ar" must additionally be selected in the FSB by
double-clicking. The FSB closes.
● Click on OK in the command area.
The data are added to the list.
- Changing Basic Optimization Data
● Click on the icon.
● Using the right mouse button, click on that line in the list that contains the data to be changed.
The data are transferred to the editing fields.
● Change the data as required and add to the list by selecting OK.
- Deleting Basic Optimization Data
● Activate the icon.
● Select the line from the list that contains the data to be deleted.
The data are deleted immediately if the option "Delete without confirm." is selected in the main
window.
The following dialog box is displayed if the option "Delete with confirm." is selected in the main
window.
● Click on Yes.
The dialog box closes, and the selected data are taken off the display.

14 Control / Control Modules User Manual Line Computer UNIX
0.2 Job Control Software Version 501.xx 01/99 Issue
14 - 16
- Searching
In the search window different search criteria, e.g. for the name of the line or the subline, are availa-
ble. Making use of a search window, the procedure is the same for all search operations (see also
page 14 - 22).
● Deactivate all icons in the command area.
● Click on the icon.
The dialog window "Search for basic optimization data" opens.
● Click on the Subline search criterion, for example.
● Enter the Search word.
● Select Search or Search additively.
The window closes and the matching data are highlighted in the selection area.
● Click on Abort if the search process is to be abandoned.
- Saving the edited basic optimization data
● Click on FILE --> Quit on the menu bar.
The following dialog box opens.
● Click on Yes in the dialog box.
The dialog box and the "Basic optimization data" window close.
The basic optimization data are saved.

User Manual Line Computer UNIX 14 Control / Control Modules
Software Version 501.xx 01/99 Issue 0.2 Job Control
14 - 17
14.1.4.5 OPTIONS Menu
- Inserting jobs into the current job list
Newly created jobs can be inserted at the top of the list (yet behind the jobs already scheduled) or at
the end of the list, or by a mouse-click.
● Select OPTIONS --> Insert --> File beginning or File end or Mouse click, respectively.
If the mouse-click option for inserting jobs is selected, the new job is inserted below the job which
is clicked-on on the current list, without
prior actuation of "OK" in the command area.
- Producibility
This menu item permits the options "Check PCB data only" and "Board Booster" for the producibility
test to be toggled on or off.
If the option "Check PCB data only" is toggled off, the data will be compiled and overwritten, if requi-
red, during the producibility test.
If the "Check PCB data only" option is activated, the processing data of the PCB will not
be over-
written during producibility check or job scheduling. The data will only be checked for consistency. If an
error in the PCB data is detected during the check, the error will be displayed and the job cannot be
scheduled.
If the option "Board Booster" is toggled on, optimization is carried out during the producibility test on the
basis of additional criteria. This leads to improved results, i.e. an increase in the placement performance,
although more time is required for calculation purposes.
● Click on OPTIONS --> Producibility --> Check PCB data only or Board Booster.
The identification mark (°) preceding the option has been changed (
¤).
NOTE
Any new
job must always be compiled first for the processing data to be created completely. For this
purpose, the "Check PCB data only" option must be de
activated (°).
° means that the option is deactivated.
¤ means that the option is activated.
By default, the options "Check PCB data only" and "Board Booster" are deactivated.
The currently applicable status of the two options is displayed in the upper right corner of the main
window of Job Control (see Fig. 14.1.1).
The most recent settings will be lost when the LC session is terminated unless they were saved using
the "Save default values" command (see page 14 - 18).
- Printer selection ...
This option is used to select a connected printer.
● Click on OPTIONS --> Printer selection ...
The window for printer selection is opened (see chapt. 2).
● Select the desired printer type.
● Confirm the selection with OK, or abort procedure with Abort.