00197458-01_UG_EDM_V2.2_en.pdf - 第74页
EDM V2.2 / U ser Guid e Ausgabe 10/2013 E dition 74 6.2.6.4 Configura tion O f EDM N otification T raffi c Key: notificationDistributorConfiguratorClass Type: Class Default: Siemens. SiplacePro.EDM.UserInterface.EmailCon…
EDM V2.2 / User Guide Ausgabe 10/2013 Edition
73
6.2.6.1 Server Type
Ke
y:
serverType
Type:
Enum
Values:
NONE
LINE
MASTER
BOTH
CLEARINGPOOL
CONFIGSERVE
R
CONFIGMASTER
CONFIGLINE
ALL
Line + Master
Config Server + Master
Config Server + Line
Config Server + Master + Line + CP + …
Valid for:
All EDM Computers running an EDM Service
Description:
Specifies the type of installation. The EDM server is started as a Line Server,
Master Server or
hybrid depending on this setting.
NOTE: The hybrid settings "BOTH" and "ALL"
should only be used for test
pur
poses!
NOTE: This value is replaced with the valu
e from the MachineConfig.xml (see 0).
This is the fallback value for EDM Computers that have no entry in the Machine
Configuration. The default value is "NONE".
6.2.6.2 Help Folder
Key:
helpDirectory
Type:
Path
Default:
[AppDir]\help
Valid for:
Line server
Master server
Clearing pool
EDM Tool
Description:
Folder for online documentation
6.2.6.3 Distribution List For EDM Notifications
Key:
notificationDistributorClass
Type:
Class
Default:
Siemens.SiplacePro.EDM.DataExchange.EmailDistributor,
DataExchange
Valid for:
Master server
Description:
Class, i.e. implementation of the notification service. At present, distribution via
email is available using the default value as a
reference.
Note:
The notificationDistributor class interface has been changed with EDM 2.1.
EDM V2.2 / User Guide Ausgabe 10/2013 Edition
74
6.2.6.4 Configuration Of EDM Notification Traffic
Key:
notificationDistributorConfiguratorClass
Type:
Class
Default:
Siemens.
SiplacePro.EDM.UserInterface.EmailConfigurator,
UserInterface
Valid for:
Master server
Description:
Configuration dialog box for the notification service. The actual configuration of the
notification service depends on its implementation. Configuration o
f an email
service referenced using the default value is currently supported.
6.2.6.5 Notification Interval
Key:
notificationInterval
Type:
Time
Default:
P0Y0M0DT0H15M0S (= 15 minutes)
Valid for:
Line server
Description:
Time period during which the change
notifications will be collected on the Line
Servers before they are sent to the Master Server. The options are as follows (from
left to right
, according to the ISO 8601 standard):
Y
= years
M
= months
D
= days
H
= hours
M
= minutes
S
= seconds
The period
should not be shorter than 5 minutes.
6.2.6.6 Notification Storage
Key:
notificationStorage
Type:
Endpoint
Default:
notificationStorage
Valid for:
Line server
Description:
Buffer for collected change notifications.
6.2.6.7 Master Server
Key:
masterServer
Type:
String
Valid for:
Line server
Master server
Clearing pool
Description:
Network ID of the Master Server. Windows computer name only. IP addresses are
not permitted.
EDM V2.2 / User Guide Ausgabe 10/2013 Edition
75
6.2.6.8 Transceiver
Key:
transceiverClass
Type:
Class
Default:
Siemens.
SiplacePro.EDM.DataExchange.MsmqTransceiver,
DataExchange
Valid for:
All EDM Applications
Description:
Implements the data transfer between the Line Servers and Master Server. This
entry must be identical on all installed systems. The exact format of the
"endpoint"
values depend on this value. The default setting uses MSMQ to transfer the data.
Endpoint:
An endpoint entry has the following format for the MSMQ transceiver:
Private$
\[queue-name].
Note that private queues absolutely must be used here. Only
private queues can
be used in both a domain/active directory
-based network environment as well as in
a pure workgroup installation.
6.2.6.9 Outgoing Requests
Key:
masterRequests
Type:
Endpoint
Valid for:
Line server
Clearing pool
Description:
Target address for service requests sent by a Line Server to the Master Server.
The setting must be identical to the
Incoming Requests setting on the Master
Server.
6.2.6.10 Outgoing Change Notifications
Key:
masterNotifications
Type:
Endpoint
Valid for:
Line se
rver
Description:
Target address for change notifications sent by a Line Server to the Master Server.
The setting must be identical to the
incoming change notifications setting on the
Master Server.
6.2.6.11 Incoming Requests
Key:
incomingRequests
Type:
Endpoint
Valid for:
Master server
Description:
Endpoint at which the Master Server listens in for incoming service requests.
Determines the value for
outgoing requests on the Line Servers.
The value must be different from the value for
incoming change notifications.