00197458-01_UG_EDM_V2.2_en.pdf - 第77页
EDM V2.2 / U ser Guid e Ausgabe 10/2013 E dition 77 6.2.6.16 Communication T imeout Key: communicationTimeout Type: T im e Default: P0Y0M0DT0H1M0S (= 1 minute) Valid for: Line serv er Master ser ver Clearing pool Descrip…
EDM V2.2 / User Guide Ausgabe 10/2013 Edition
76
6.2.6.12 Incoming Change Notifications
Key:
incomingNotifications
Type:
Endpoint
Valid for:
Master server
Description:
Endpoint at which the Master Server listens in for incoming change notifications.
Determines the value for
outgoing change notifications on the Line Servers.
The value must be different from the value for
incoming requests.
6.2.6.13 Incoming Clearing Pool Requests
Key:
incomingClearingPoolRequests
Type:
Endpoint
Valid for:
Master server
Clearing pool
Description:
Endpoint at which
the Clearing Pool listens for incoming commands from the
master service.
6.2.6.14 EDM Tool Endpoint
Key:
edmToolEndPoint
Type:
Endpoint
Default:
EDM_SPI_REMOTE_HOST:9002/EdmTool
Valid for:
Master server
Line server
EDM Tool
Description:
Endpoint for entering change notifications. The default value
means that the
comment dialog boxes always open on the computer at which the SPI event was
triggered that caused the notification which requires a comment (if an EDM tool is
installed there).
R
eplace EDM_SPI_REMOTE_HOST in the configuration file of the Line Server with
the host name of this computer
, if the line engineer shall enter the comments at a
different computer
.
6.2.6.15 Endpoint Configuration
Key:
endpointConfig
Type:
Section
Valid for:
Master
server
Description:
This section contains pairs of values
in the form of:
<add key=
"[hostname]" value="[Endpoint]"/>
There is one pair of such values for each Line Server. This list describes the
connections from the Master Server to the Line Servers to
be used.
The network ID (not the alias) of the computer concerned must be entered under
hostname. You can also enter
"*" or "all" as the value for hostname. This is
then used as the default value when no entry can be found for a specific Line
Server.
Impor
tant: All Line Servers should always be listed in every configuration file. In
particular, the name of the local computer must be included (or at least an entry for
"*"
).
EDM V2.2 / User Guide Ausgabe 10/2013 Edition
77
6.2.6.16 Communication Timeout
Key:
communicationTimeout
Type:
Time
Default:
P0Y0M0DT0H1M0S (= 1 minute)
Valid for:
Line server
Master server
Clearing pool
Description:
Time period in which a message must be received from a particular communication
partner. The setting should generally not be changed. The other options are as
follows (from
left to right):
Y
= years
M
= months
D
= days
H
= hours
M
= minutes
S
= seconds
6.2.6.17 Using Advanced EDM Notification Filtering
Key:
useAdvancedNotificationFiltering
Type:
Boolean
Default:
true
Valid for:
Master server
Description:
Activation/deactivation
of direct import/rejection of notifications by the Master
Server.
If these filters are deactivated, all notifications are entered in the Clearing Pool. If
they are activated, changes to objects can be accepted/rejected
without first being
displayed in the Cleari
ng Pool.
6.2.6.18 Modified Object Protection
Key:
useModifiedObjectProtection
Type:
Boolean
Default:
true
Valid for:
Line server
Description:
Activation/deactivation of the overwriting of modified objects in the Line
Server.
If this object is activated, objects which are currently in the Clearing Pool are not
overwritten with the (older) data from the Master Server during a pull operation.
EDM V2.2 / User Guide Ausgabe 10/2013 Edition
78
6.2.6.19 Response Timeout
Key:
responseTimeout
Type:
Time
Default:
P0Y0M0DT0H5M0S (= 5 minutes)
Valid for:
Line server
Description:
Time period in which the Line Server considers a reply to a service request from
the Master Server to be valid. Timing problems can arise here due to the
interaction between SIPLACE Pro and XML Import/Exp
ort that may require a
change to be made. However, the timeout should not be set to a value too high
since this can cause the users to become very irritated.
The other options are as follows (from left to right):
Y
= years
M
= months
D
= days
H
= hours
M
= minutes
S
= seconds
6.2.6.20 Compression Type And Level
Key:
compressionType
Type:
Enum
Values:
None
Zip
Bzip
Default:
Zip
Valid for:
All EDM applications
Description:
Compression mode for the data transfer. The setting must be identical throughout
the
entire system.
The default setting represents a good compromise between the compression ratio
and processing time. If extremely large amounts of data are transferred by the
customer, it may be necessary to set the compression to
Bzip. This method offers
a
much higher compression ratio than Zip, but at the cost of longer processing
times. Compression should only be switched off when the amount of data is always
very small (< 4MB).
Even though EDM tries to auto
-detect the compression type it is strongly
recom
mended to use the same compression type in all configurations when
working with different SystemConfigurations for multiple config sets.
6.2.6.21 Client Workflow Configuration
Key:
clientWorkflowConfig
(Obsolete now part of the Configuration
Set)
Type:
File
Default:
Clientworkflowconfig.xml
Valid for:
-
Description:
Definition of the workflow on the EDM Client. The file name is specified relative to
the configuration folder.