OM-1683-001_w.pdf - 第41页
24 OM-1683 1 103-001 12.2 "PCB T ransfer Mode" T ab Sheet 12.2 "PCB T ransfer Mode" T ab Sheet This enables the operat or to setup the mode in the input and output m achines. Reference Refer to "…

23
OM-1683
1103-001
12.1 "Chute Level" Window
12.1 "Chute Level" Window
[1]
Fig. 23 Chute Level
[1] Chute Level
When the single transfer mode is setup and the PCB size is over 290 mm,
this offset is used to adjust the difference in the positioning height between
the lanes.
Lane A Chute Upper Surface
PCB
(-)
(+)
Support Pin
Backup Base
Difference
A-BL B-BL
Lane B Chute Upper Surface
PCB
2 Clamps
Origin
Fig. 24
Graphic
Development

24
OM-1683
1103-001
12.2 "PCB Transfer Mode" Tab Sheet
12.2 "PCB Transfer Mode" Tab Sheet
This enables the operator to setup the mode in the input and output machines.
Reference
Refer to "3.2 "PCB Transfer Mode" Window" in Chapter 2, Volume 3, in
the SIGMA-G5 main machine instruction manual for the information other
than for dual transfer.
[2]
[1]
[1]
[2]
[3]
[4]
Fig. 25 PCB Transfer Mode
•
Commonness
The common setting for the input and output machines to the lanes is
performed.
[1]
A Lane Simult. trans. Set-up
B Lane Simult. trans. Set-up
Set "Enable" or "Disable" to determine whether or not the PCB transfer
should be made simultaneously between the input and positioning conveyors
and between the positioning and output conveyors.
Enable
:
The simultaneous transfer setup function is
used.
Disable (Independent)
: The simultaneous transfer setup function is not
used.
Disable (Asynchronous)
: When the transferred PCB passes the inlet
sensor at the output conveyor, the next PCB
transfer movement is started.
[2]
A Lane OutP conv. PCB out
B Lane OutP conv. PCB out
Set "Disable" or "Enable" to determine whether or not a disengaged PCB
should be detected in the output conveyor section.
Graphic
Development

25
OM-1683
1103-001
12.2 "PCB Transfer Mode" Tab Sheet
[3] A Lane standard chute position [mm]
The standard chute position in the lane A is set in this text box.
[4]
Output mode
The method for the PCB transfer to the output machine is setup in this
selection box.
The method for the PCB transfer to the output machine from the two lanes in
the dual transfer mode, is selected from the following items.
Alt output (A
lane)
When selected, the PCBs on which the component placement has been
completed, are discharged alternatively from the Lane A.
Alt output (B lane)
When selected, the PCBs on which the component placement has been
completed, are discharged alternatively from the Lane B.
•
A
Lane, B Lane
The setting for the input and output machines for each lane is performed.
Fig. 26