OM-1683-001_w.pdf - 第51页
34 OM-1683 1 103-001 13.3 Maintenance Spots 13.3.2 Inspection, Cleaning, and Lubrication stops 13.3.2.1 PCB Positioning Section Ball Screws Ball Screws (2 Places) Every 3 Months Cleaning and Lubrication (DAPHNE EPONEX GR…

33
OM-1683
1103-001
13.3 Maintenance Spots
13.3 Maintenance Spots
13.3.1 Whole View
Notice
Any operations with a cover(s) being removed are included.
After the maintenance work, be sure to attach the cover.
Feeder Cart Section
Air Source
Vacuum System
Front View of Machine
Fig. 29
Reference
Refer to "13.3.2" and the subsequent items for the detailed information on the
spots of each section to be maintained and how to maintain them.

34
OM-1683
1103-001
13.3 Maintenance Spots
13.3.2 Inspection, Cleaning, and Lubrication stops
13.3.2.1 PCB Positioning Section
Ball Screws
Ball Screws (2 Places)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 10 minutes
Wipe off old grease with a rag and apply new
one with a syringe.
Take ample care not to leave any
waste threads after cleaning.
Grease should be applied every 3 months after
the initial month.
Use No. 19 (brown) nozzle.
No. 19
Ball Screw Splines
(Grease Nipple 6 places)
Every 6 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 10 minutes
(1) Wipe off old grease with an oiled rag.
(2) Attach the SPK-3C attachments to a hand
grease gun and supply new grease to the
grease nipples with the hand grease gun.
Take ample care not to leave
any waste threads after
cleaning.
Notice
SPK-3C
Upper Surface of Backup Table
Every Week Cleaning
Required Time: 2 minutes
Remove foreign substances and unrequired components
and suck dirt and dust with a vacuum cleaner.
Notice
Note
Fig. 30

35
OM-1683
1103-001
13.3 Maintenance Spots
13.3.2.2 Conveyor Section
Type H
PT1/8
Lubrication Work Example
Linear Guides (2 places)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
Wipe off old grease with an oiled rag.
Take ample care not to leave any
waste threads after cleaning.
Use type H nozzle.
Notice
Note
Attach the H-type attachments to a hand grease
gun and supply new grease to the grease nipples
with the hand grease gun.
Fig. 31