YC8_Ope_E.pdf - 第37页
1-2 1 Part names and functions Machine main unit Rear view Machine-to-machine interface connector (Behind lower left cover and lower right cover) Operation panel buttons (option) A TS15 (option) 23101-N8-00

1-1
1
Part names and functions
1. Machine main unit
A standard machine has the following configurations after installation is complete. Names and functions of
major parts of the main unit are illustrated below.
Signal light
Operation panel and
data input unit
Power switch
Alarm buzzer
Safety cover
Pressure gauge
Air pressure supply/
shutoff switch
Power connection terminals
Machine main unit
Front view
USB port
Tape reel holder
(option)
Feeder setup section
Behind lower left door Behind lower right cover
23100-N8-00

1-2
1
Part names and functions
Machine main unit
Rear view
Machine-to-machine interface connector
(Behind lower left cover and lower right cover)
Operation panel buttons (option)
ATS15 (option)
23101-N8-00

1-3
1
Part names and functions
n
Signal light
Indicates current operating conditions of the mounter with a green, yellow and red light, or green, white and blue light
explained below. (The color of the signal light when a buzzer sounds can be selected from two patterns (option).)
Machine status Example Green
Red/
White
Yellow/
Blue
Warm-up or automatic operation ON ----- -----
Emergency stop ----- ON -----
System error
(with buzzer ON)
• Excessive current
• Secondary limit over
----- ON -----
Operation or board data error
(with buzzer ON)
• Pickup error, recognition error
• Data check error, etc.
----- ----- ON
Components cannot be used. • Components run out. ----- ----- Flashing
n
Alarm buzzer
This buzzer sounds if an error or abnormal operation occurs. (The color of the signal light when a buzzer sounds can be
selected from two patterns (option). (The buzzer volume can be adjusted by turning the buzzer ring right or left.)
n
Safety cover
This cover must be closed during operation. If opened, emergency stop is triggered.
n
Pressure gauge
Shows the supply air pressure (upper display) and pressure-drop detection level (lower display). Use the pressure
regulator knob and the pressure-drop detection level adjust buttons on the pressure gauge to set each pressure value as
follows:
• Supply air pressure (upper display) : 0.40 MPa
• Pressure-drop detection level (lower display) : 0.33 MPa
n
Head assembly
Picks up and mounts components with the nozzles at the tip. The head assembly also has two cameras: one for scanning
and recognizing components and the other for recognizing marks on boards. (See "3. Head assembly" in this chapter.)
n
Behind front lower left panel
An air supply/shutoff switch and USB ports are located.
n
Power switch
Turns on or off the power to the machine. The power is on when turned to the right.
c
Wait about 2 seconds before turning the power switch back on after turning it off.
n
Feeder setup section
Mainly tape feeders are installed here. (See "4.1 Supplying components from feeder plates" for details.
n
Tape reel holder (option)
This is installed in front of the feeder set section and holds tape reels in place.
n
Connection between machines (input/output signals between machines)
The mounter ejects the finished board when it receives a signal from the machine in the next process, and then sends a
signal to the machine in the preceding process to request another board. The interface connector labeled "NEXT
INTERFACE" connects to the machine in the next process, and the interface connector labeled "PREVIOUS INTERFACE"
connects to the machine in the preceding process.
In the case of standard machines of right-to-left flow, the PREVIOUS INTERFACE connector is located behind the rear
right cover of the machine, and the NEXT INTERFACE connector behind the rear left cover.