YC8_Ope_E.pdf - 第91页

2-41 2  asic operation 5.2 Operation check n Checking the feeder operation 1 Open the feeder screen. Press the [Unit] button and then select t he [Feeder] tab to open the feeder screen. 2 Select the feeder and check the…

100%1 / 122
2-40
2
asic operation
n
When using tray components
6
Set the "Feeder Type" parameter.
Select "Auto TC" from the drop-down list.
[Parts]-[Basic] screen
"Feeder Type" parameter
"Feeder Type"
24226-N8-00
2-41
2
asic operation
5.2 Operation check
n
Checking the feeder operation
1
Open the feeder screen.
Press the [Unit] button and then select the [Feeder] tab to open the feeder screen.
2
Select the feeder and check the operation.
1. From the feeder layout diagram or feeder list, select the feeder to check the operation.
2. Press the [Feed] button on the lower right of the screen to check whether tape is fed correctly.
Feeder screen
Selecting the feeder
Feeder list
Feeder layout diagram
[Feed] button
24227-N8-00
n
NOTE
When a feeder with a pitch of 4mm or more is installed, check the top component and its position.
n
Checking the tray changer operation
1
Open the tray changer screen.
Press the [Unit] button and then select the [Auto TC] tab to open the tray changer screen.
2
Extract a pallet from the tray changer.
Press the [Pallet Set] button to check whether a pallet is correctly extracted from the tray changer.
Tray changer screen
Selecting a pallet
[Pallet Set]
button
Enter a pallet number
24228-N8-00
Chapter 3 Starting and ending production
Contents
1. Starting production 3-1
1.1 Resuming operation from the stopped point 3-6
1.1.1 Loading the saved data 3-7
1.1.2 Editing mount flags 3-7
2. Ending production and turning power off 3-8
  0
3.1 Production 3-10
  2
  4
  6
3.5 Alignment 3-18
3.6 Retry 3-19
  0
  1
  2
3.10 Pick Rate Warning 3-24