YC8_Ope_E.pdf - 第88页
2-38 2 asic operation 3 Open the P arts screen. Press the [Parts] button to open the Parts screen and select the component from the upper list . Parts screen 24222-N8-00 4 Displa y the basic par ameters. Select the [Ba…

2-37
2
asic operation
5. Settings on the mounter side
After installing the tape feeders in the surface mounter, you must make settings for the mounter.
5.1 Setting the "Package" parameter.
On the [Parts] – [Basic] tab screen, you must set the "Package" and "Tape Type" parameters.
1
Open the "Board data select" screen.
On the Setup screen, press the [Board] to open the "Board data select" screen.
Setup screen
[Board] button
[Board] button
24220-N8-00
2
Select the board data.
Select the board data in the list and press the [Select] button.
"Board data select" screen
Select the board data.
24221-N8-00

2-38
2
asic operation
3
Open the Parts screen.
Press the [Parts] button to open the Parts screen and select the component from the upper list.
Parts screen
24222-N8-00
4
Display the basic parameters.
Select the [Basic] tab to display the basic parameters.
5
Set the "Package" parameter.
Double-click the "Package" parameter field and select "Tape", "Stick" or "Tray" from the drop-down list
according to the component supply unit to be used.
[Parts]-[Basic] screen
"Package" parameter
"Package"
24223-N8-00
c

2-39
2
asic operation
n
When using tape components
6
Set the "Tape Type" parameter.
Double-click the "Tape Type" parameter field and select the tape type from the drop-down list.
The "Tape Type" parameter changes as the "Package" parameter is changed, so set it to the correct
setting.
[Parts]-[Basic] screen
"Tape Type" parameter
"Tape Type"
24224-N8-00
n
NOTE
This parameter does not appear when "Reference of feeder pitch" is set to "Feeder setup".
7
Set the feed pitch.
Double-click the "Pitch Index" parameter field and select the correct feed pitch from the drop-down list.
[Parts]-[Basic] screen
"Pitch Index" parameter
"Pitch Index"
24225-N8-00