Installation Fitting the Sensors for the TwinHead Fitting the Sensors Option Verify Reject Bin Option Abfrage Abwurfbehälter 65 ► Take the long cable W1 fr om sensor S1 and guid e the cable th rou gh the recesses on the …

Installation
Fitting the Sensors Fitting the Sensors for the TwinHead
64 Option Verify Reject Bin Option Abfrage Abwurfbehälter
3.1.2.2 Fitting the Sensors for the TwinHead with MTC for CAN Node Infrastructures
► Fit the connector X2*q of the "reject bin sensors for upgrade" [03079029-xx] cable between the con-
nectors for the CAN nodes [03035229-xx] and that for the standard sensors [03022078-xx]. (See
also the diagram "Overview of sensors for CPP") in section "3.1.1 Fitting Sensors for C&P20 and
CPP" [ ➙ 56])
► Using SW70x an additional adapter [03086762-xx] is required. Please also observe the diagrams in
section "3.1.2 Fitting the Sensors for the TwinHead" [ ➙ 61].
NOTICE
CAN nodes
► The CAN node option also requires a cutter.
► Machines with the CAN node infrastructure and an MTC at locations with a TwinHead must
use the "upgrade sensor cable reject bin" [03079030-xx].
Fitting the upgrade "reject bin sensor cable"
[03079029-xx]
1. X2*q cable for feed device X series: reject bin
[03053229-xx]
2. Cable X series/HF R2: reject bin [03022078-xx]
3. Cable: reject bin sensors for upgrade [03079029-xx]
4. Sensor cable
Sensor S2 in the park position for X series machines
► Take the short cable W2 from sensor S2 and fit it (1)
with the sensor plate [03006260-xx] (2) at the park
position of the component feed device.

Installation
Fitting the Sensors for the TwinHead Fitting the Sensors
Option Verify Reject Bin Option Abfrage Abwurfbehälter 65
► Take the long cable W1 from sensor S1 and guide the cable through the recesses on the machine
base to the location with the MTC.
► Remove the reject bin.
► Fix sensor S1 to the bracket under the large component reject bin with the two plastic screws M3x10.
► Replace the bin.
Routing the cable for the component reject bin sensor of
the TwinHead at the location with the MTC
1. Sensor S1 reject bin at location with component feed
device
2. Recesses on machine base at location 1/3
3. Sensor S2 reject bin at location with MTC
4. Recesses on machine base at location 2/4

Installation
Fitting the Sensors Fitting the Sensors for the TwinHead
66 Option Verify Reject Bin Option Abfrage Abwurfbehälter
3.1.2.3 Fitting the Sensors for the TwinHead with MTC on the 1 Wire Hub
If the TwinHead is installed in a 2 gantry placement area with MTC, sensor S1 can be fitted to the com-
ponent reject bin carrier as described above. Sensor S1 must be fitted to the TwinHead nozzle changer
[00119717-xx].
► Fit sensor S2 in the park position on the TwinHead nozzle changer carrier [00119717-xx].
► Screw the sensor plate [03006260-xx] provided into place, at the sensor.
► Fix the cable to suitable points, so that is is not at risk of damage.
NOTICE
This only applies in conjunction with the 1 wire hub.
Sensor S2 in park position for the TwinHead, nozzle
changer with MTC
1. Sensor S2
2. Sensor plate [03006260-xx]
3. Plastic screws