00194716-04_AI_Abwurfbehaelter_Abfrage_X-D3_de_en.pdf - 第66页
Installation Fitting the Sensors Fitting the Sensors for the TwinHead 66 Option Verify Reject Bin Option Abfrage Abwurfbehälter 3.1.2.3 Fitting the Sensors for the TwinHead with MTC on the 1 W ire Hub If the TwinHead is …

Installation
Fitting the Sensors for the TwinHead Fitting the Sensors
Option Verify Reject Bin Option Abfrage Abwurfbehälter 65
► Take the long cable W1 from sensor S1 and guide the cable through the recesses on the machine
base to the location with the MTC.
► Remove the reject bin.
► Fix sensor S1 to the bracket under the large component reject bin with the two plastic screws M3x10.
► Replace the bin.
Routing the cable for the component reject bin sensor of
the TwinHead at the location with the MTC
1. Sensor S1 reject bin at location with component feed
device
2. Recesses on machine base at location 1/3
3. Sensor S2 reject bin at location with MTC
4. Recesses on machine base at location 2/4

Installation
Fitting the Sensors Fitting the Sensors for the TwinHead
66 Option Verify Reject Bin Option Abfrage Abwurfbehälter
3.1.2.3 Fitting the Sensors for the TwinHead with MTC on the 1 Wire Hub
If the TwinHead is installed in a 2 gantry placement area with MTC, sensor S1 can be fitted to the com-
ponent reject bin carrier as described above. Sensor S1 must be fitted to the TwinHead nozzle changer
[00119717-xx].
► Fit sensor S2 in the park position on the TwinHead nozzle changer carrier [00119717-xx].
► Screw the sensor plate [03006260-xx] provided into place, at the sensor.
► Fix the cable to suitable points, so that is is not at risk of damage.
NOTICE
This only applies in conjunction with the 1 wire hub.
Sensor S2 in park position for the TwinHead, nozzle
changer with MTC
1. Sensor S2
2. Sensor plate [03006260-xx]
3. Plastic screws

Installation
Fitting the Sensors with C&P6/12 Fitting the Sensors
Option Verify Reject Bin Option Abfrage Abwurfbehälter 67
3.1.3 Fitting the Sensors with C&P6/12
Overview of sensors with C&P6/12 (DLM3)
► Fix the sensor S2 to the sensor carrier [03021179-xx] with the 2 plastic screws DIN85-M3x6-PA
[00305381-xx].
► Fix the fixture bracket (with the sensor on it) to the component reject bin carrier (2 screws DIN912-
M3x6).
► If a nozzle changer is fitted, fit sensor S2 for the nozzle reject bin. Use the 2 plastic screws DIN85-
M3x6-PA [00305381-xx] for this.
NOTICE
Screws
Only use the plastic screws provided!
Sensor component reject C&P6/12 (DLM) on the X series
machines
1. Fixture bracket
2. Sensor S1