Installation Final Wo rk Circuit Diagram for Sensors w ith 1 Wire Hub Module 78 Option Verify Reject Bin Option Abfrage Abwurfbehälter

100%1 / 82
Installation
Circuit Diagram for Sensors with 1 Wire Hub Module Final Work
Option Verify Reject Bin Option Abfrage Abwurfbehälter 77
3.4 Final Work
Use cable ties to fix all cables to suitable points. Make sure that no cables or hoses can be damaged
or pinched.
If you have disconnected the component trolley feed device, refit this. Please read the latest service
manual for the relevant machine prior to this.
Refit the nozzle changer and reconnect it.
Remove any assemblies which are not required and tools used from the machine. Check whether
the gantries and heads can move unobstructed in the machine and ensure that there is no risk of
collisions.
Switch on the machine.
SW60x: message for verify reject bin option
Check the settings with the help of the station soft-
ware. This shows the presence of the individual reject
bins. Use the user interface to make sure that all re-
ject bins are queried and shown correctly.
If necessary, recheck the setting for the reject bin 6x6
sensor of the C&P20 or CPP head.
Measure the nozzle changer and the pickup positions
of the changeover tables.
Installation
Final Work Circuit Diagram for Sensors with 1 Wire Hub Module
78 Option Verify Reject Bin Option Abfrage Abwurfbehälter
Appendix
Test Mode Sensor for FCU
Option Verify Reject Bin Option Abfrage Abwurfbehälter 79
4 Appendix
4.1 Test Mode Sensor for FCU
A test mode is available on the FCU for machines with the sensor control above the FCU. The machine
needs to be switched on for this.
The FCU may differ depending on the machine type:
SX4 or X series: X-FCU/X series (without CAN node or 1-Wire-Hub) [03059623-xx]
SX1/SX2: B-FCU/B series [03059666-xx]
Test mode
To enable the test mode, set the switch S1 to "OFF".
Test mode FCU - Example: FCU for 60 feeder modules (SX1/SX2)
The LED display on the right, next to the row of switches, is used to check the functionality of the reject
bin sensors.
Switch ON (0) OFF (1)
S1 Test mode, switched off Test mode, switched on
S2 FCU for 60 feeder modules (SX1/SX2) FCU for 40 feeder modules (X series and
SX4)
S3 Feed control with virtual button Feed control without virtual button
S4 "HW version 8" with control system for tape
cutter, reject sensor and nozzle changer
function
"HW version 8" without control system for
tape cutter, reject sensor and nozzle chang-