00194716-04_AI_Abwurfbehaelter_Abfrage_X-D3_de_en.pdf - 第67页

Installation Fitting the Sensors with C&P6/12 Fitting the Sensors Option Verify Reject Bin Option Abfrage Abwurfbehälter 67 3.1.3 Fitting the S ensors with C&P6/12 Overview of sensors with C&P6/12 (DLM3) ► Fi…

100%1 / 82
Installation
Fitting the Sensors Fitting the Sensors for the TwinHead
66 Option Verify Reject Bin Option Abfrage Abwurfbehälter
3.1.2.3 Fitting the Sensors for the TwinHead with MTC on the 1 Wire Hub
If the TwinHead is installed in a 2 gantry placement area with MTC, sensor S1 can be fitted to the com-
ponent reject bin carrier as described above. Sensor S1 must be fitted to the TwinHead nozzle changer
[00119717-xx].
Fit sensor S2 in the park position on the TwinHead nozzle changer carrier [00119717-xx].
Screw the sensor plate [03006260-xx] provided into place, at the sensor.
Fix the cable to suitable points, so that is is not at risk of damage.
NOTICE
This only applies in conjunction with the 1 wire hub.
Sensor S2 in park position for the TwinHead, nozzle
changer with MTC
1. Sensor S2
2. Sensor plate [03006260-xx]
3. Plastic screws
Installation
Fitting the Sensors with C&P6/12 Fitting the Sensors
Option Verify Reject Bin Option Abfrage Abwurfbehälter 67
3.1.3 Fitting the Sensors with C&P6/12
Overview of sensors with C&P6/12 (DLM3)
Fix the sensor S2 to the sensor carrier [03021179-xx] with the 2 plastic screws DIN85-M3x6-PA
[00305381-xx].
Fix the fixture bracket (with the sensor on it) to the component reject bin carrier (2 screws DIN912-
M3x6).
If a nozzle changer is fitted, fit sensor S2 for the nozzle reject bin. Use the 2 plastic screws DIN85-
M3x6-PA [00305381-xx] for this.
NOTICE
Screws
Only use the plastic screws provided!
Sensor component reject C&P6/12 (DLM) on the X series
machines
1. Fixture bracket
2. Sensor S1
Installation
Fitting the Sensors Fitting the Sensors with C&P6/12
68 Option Verify Reject Bin Option Abfrage Abwurfbehälter
Nozzle reject bin sensor for C&P6/12 (DLM)
1. Sensor 1
2. Sensor 2
Sensor S2 in park position
If there is no nozzle changer fitted, fit sensor S2 (1) in
the park position.
Screw the sensor plate [03006260-xx] (2) provided
into place, next to the sensor.
If there is a second nozzle changer row fitted in the
placement area with the C&P6 or C&P12 placement
head, we recommend insulating the edge of the pro-
tective sheet with a suitable edge protector (1) or ad-
hesive tape. Thus any damage of the reject bin
sensor cabels can be avoided.