a2-100-en(v3_0).pdf - 第3页

A2 Automatic Dispenser V3 .0 1 1. Using Requirements 1) Please read the manual carefully before installation and operat ion. 2) W orking environment te mperat ure: 0 ℃~ +55 ℃ , relative humidity: 15% ~ 90%. Tr ansform at…

100%1 / 18
Contents
1.Using Requirement……………………………………………………………1
2.Specifications…………………….……2
3.Safety Instructions………………………………………….………………………………2
4.Machine Composition………………………………………………………………3
5.Installation…………………….……4
5.1 Installing Machine…………………………………………..……………………………………4
5.2 Installing Computer……………………………………………………………………………5
5.3 Installing Software……………………………………………………………………..………6
6.Machine Adjustment…………………………………………………………………..…………6
6.1 Software Adjustment……………………………………………………………………..………6
6.2 Machine Adjustment………………………………………………………………………..……6
6.3 Add Colorant…………………………………………………………………………..……7
6.4 Emptying Pump…………………………………………………………………..……………7
6.5 Calibration of Colorants………………………………………………………………………8
7.Operation……………………………………………………………………….……8
7.1 Put the Base Paint Can…………………………………………………………………………8
7.2 Changing the Water of the Cleaning Box…………………………………………………………9
8.Maintenance…………………………………………………………………………………….……12
8.1 Daily Maintenance………………………………………………………………..………………12
8.2 Periodical Maintenance……………………………………………………………..…………12
9.Replacing Spare Parts………………………………………………………………………………12
10.Circuit Diagram…………………………………………………………………..………………13
11.Troubleshooting…………………………………………………………………………………14
Warning Labels
Electrical Shock Danger! Cut off power supply before cleaning and maintenance.
Important Information! Read carefully.
A2 Automatic Dispenser V3.0 1
1. Using Requirements
1) Please read the manual carefully before installation and operation.
2) Working environment temperature: 0℃~+55, relative humidity: 15%90%. Transformation and storage
temperatures shall be within a range of -10 to +55 and for short periods not exceeding 24h at up to
+60
3) The machine is for indoors use only.
4) The machine is not explosion-proof, neither the machine as a whole nor its internal components are intended
for use in potential explosive atmospheres.
5) Do keep the children away from the machine. Do not operate the machine except for the staff
6) Do provide separate power supply socket and overcurrent protection device for this machine. Make sure the
loading capacity of the socket shall be in line with the requirements listed in the Nameplate. Please provide
every single phase at least 1.5mm² power supply wire for this machine.
7) Please confirm that there is dependable ground wire with the electrical socket before usage
8) Before installation and maintenance, must cut off the power supply and Unplug from outlet.
9) Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord
10) Do not operate any appliance with a damaged cord or plug, or after the appliance malfunctions or is dropped
or damaged in any manner. Return appliance to the nearest authorized service facility for examination, repair,
or electrical or mechanical adjustment.
11) Do not lengthen the power line at pleasure in case of accident
12) Keep this machine on the solid ground, then adjust the foundation to make the foundations on a horizontal
status before working
13) Do not operate the machine in case the machine shell is removed.
14Computer Composition
1
CPU PIII
2
CD-ROM Driver
3
15 Inches Monitor, screen resolution is 1024X768 pixels or
higher
4
USB/COM Interface
5
Windows 2000 or higher Operating System
A2 Automatic Dispenser V3.0 2
2. Specifications
TypeA2 ModelA2-100%/Hummingbird
Item
Content
Item
Number of Canisters
16/14/12/10
Min Dispensing
Hummingbird-0.015ml(1y/2000))
Max Flow Rate
0.60ltr/min
Canister Size
Pump Size
62mltr
Stirring Speed
Power
≤100W
Power Supply
Can Size
(D x H)
MAX 320mm x 400mm
MIN 80mmX100mm
Stirring Timing
Noise Level
70dBA
Weight
Machine Size (Height x Width x Depth)
1300X710X840mm
NotesStirring time is available for customerization
3. Safety Instructions
1. Please read this manual carefully before installation and operation.
2. Only trained professionals are allowed for operation and/or maintenance.
3. Prolonging wire is prohibited.
4. The machine is only available for 0.5 liter to 20 liter (40kg) paint cans.
5. The machine should be powered on all the time to make the stirring available.
6. The side door shall be closed prior to close the top cover.
7. Press the emergency stop button, the machine will stop working and the stirring will stop at the same time.
8. If it is not used for a long time, the canisters should be cleaned and plugged off.
9. During transportation, the machine should be leveled, preventing from being shocked, pressed, and bottomed
up or side faced on the ground. The machine should be kept in ventilated and dry room which is
moisture-proof fire-proof.
10. It is forbidden to work the machine in the inflammable and explosive environment.
11. No hot-plug of the serial port line.