Technical Service Manual 34 Revision Dat e: August 2004 GROUNDING PROBLEMS The oven is indicating what appear to be random high tem peratures due to a gr ounding problem . POSSIBLE CAUSES Each T /C is grounded at the con…

Technical Service Manual 33 Revision Date: August 2004
THERMOCOUPLE CONNECTION
The oven is indicating what appears to be a random high temperature due to a bad thermocouple
connection.
POSSIBLE CAUSES
This condition is an indicator error, because the actual temperature is probably acceptable. When a thermocouple gets
open in its conductor(s), it indicates the maximum possible temperature. It produces a higher indicated temperature than
expected. It is also possible to have the open exist for one sample time and not for the next sample time, thereby
producing a short indication of maximum temperature and then normal temperature immediately after. If the connection
is not open but simply high resistance, then the temperature indication could be higher than the actual temperature.
HINT: Check the connector(s) where the T/C plugs into the conductors on top of the cell and the terminations at the
controller.
CONVEYOR MOTOR NOISE
The oven is indicating random high temperatures due to conveyor motor noise.
POSSIBLE CAUSES
The conveyor motor is a DC motor with a set of brushes, which may emit a high, pitched audible noise. When the
brushes make this noise, they are also generating electrical noise, which can be transmitted to various parts of the oven
through the wiring. The T/C conductors are not shielded, so it is possible for the T/C conductors to pick up electrical
noise from nearby wires. The electrical noise on the T/C conductors can cause the system to indicate random high
temperatures.
If the conveyor motor is noisy, try replacing the motor brushes, the motor or shielding the T/C wire for its entire length in
the oven.
AC ON T/C or T/C WIRES
The oven is indicating random high temperatures due to an AC signal on the thermocouple or the
thermocouple wires.
POSSIBLE CAUSES
This is very similar to the conveyor motor noise problem.
THERMOCOUPLE / CONDUCTORS: The AC on the T/C or T/C wires is interpreted by the controller as a higher
temperature. Since the AC is not the normal signal, it is intermittent and random. The AC is closer to the controller than
the T/C so it shows up as a higher temperature than normal.
HINT: Disconnect the T/C at the controller (Jumper T/C terminals on controller) and check for the AC with an
oscilloscope. If it is still on the T/C wires, disconnect the T/C at the top of the cell to isolate the problem from the inside of
the cell or the wiring in the oven.
FRAME: Make sure that the AC is not on the oven frame. (Since the T/Cs are grounded, AC on the oven frame can
show up on the T/Cs.)
25
26
27

Technical Service Manual 34 Revision Date: August 2004
GROUNDING PROBLEMS
The oven is indicating what appear to be random high temperatures due to a grounding problem.
POSSIBLE CAUSES
Each T/C is grounded at the controller when it is properly connected. If there is a poor connection to ground at this point,
the T/C reading will be unreliable and will indicate random high temperatures.
Check the ground connection AT THE CONTROLLER. Make sure that it is correct.
Use an Ohmmeter to check the connections and refer to the oven prints to make sure that the connections are correct.
(The grounding problem is usually electrical noise on the ground or a faulty facility ground with high resistance. This can
result in the noise affecting the T/C reliability.
(FOR FUTURE USE)
EXTERNAL AIR FORCED INTO HEAT TUNNEL
The oven is exhibiting random low temperatures due to external air entering the oven tunnel.
POSSIBLE CAUSES
ICBs (inter cell baffles): If the ICBs are improperly adjusted, it allows air from outside to enter the oven tunnel, resulting in
random low temperatures (Refer to the chart of initial slot settings for the oven.)
EXTERNAL DISTURBANCES: The reflow process is also susceptible to external cold air and large airflow events outside
the oven. For instance, locating the oven next to a large loading dock area could cause this problem. The XPM Series
ovens are not very susceptible to external influences, but under the right circumstances, this is a possibility.
AIR LEAKS: Check for air leaks in the oven tunnel.
(External air forced into the Oven tunnel usually affects only the first 1 or 2 zones)
28
29
30

Technical Service Manual 35 Revision Date: August 2004
RADICAL RECIPE CHANGE
SYMPTOMS 1 through 6
For all of the following symptoms:
1. Temperature =< 10 degrees above setpoint and stable
2. Temperature slow rise past set point
3. Temperature rapid rise past set point
4. Temperature rises but doesn’t reach set point
5. Temperature appears to stay cold
6. Temperature drops from set point
POSSIBLE CAUSES
A radical change in the running recipe can cause these symptoms. An example of a radical change would be switching
from a reflow recipe to a curing recipe or vice versa. If you are experiencing this problem and cannot work around it, call
the Vitronics-Soltec Field Service or Applications Support departments for assistance.
(FOR FUTURE USE)
31
32