00196500-05_IM_SSW_703_03_DE EN.pdf - 第11页
Installation Manual, Station Software Version 703.03 01/2011 Edition 3.4 Upgrading from 60x sof tware versi ons (X-series placement machines) By upgrading from 60x station software versions, a complete reinstallation/rec…
Installation Manual, Station Software Version 703.03 01/2011 Edition
10 of 54
3.2.2 X-series placement machines
→ Install the 703.03 machine computer software for two-computer operation, see chapter 5.
→ Install the Vision computer software, see chapter 6.
→ Shut down the machine.
→ Remove the tables.
→ Switch on the machine again and perform the eSW download.
→ Reboot the machine.
→ Place the tables.
The eSW download for the feeders starts automatically.
→ Save the calibration data for the placement heads in the EEPROM (see section 7.4).
→ Start the production.
3.3 Upgrading from 701.xx software versions (X4I placement machine)
→ Download the SIPLACE_UpgradePreparation.exe file (directory Upgrade_Preparation) from the
installation CD and execute the file.
→ Reboot the machine and perform an eSW download for the placement heads.
→ Install the 703.03 machine computer software for two-computer operation, see chapter 5.
→ Install the Vision computer software, see chapter 6.
→ Shut down the machine.
→ Remove the tables.
→ Switch on the machine again and perform the eSW download.
→ Reboot the machine.
→ Place the tables.
The eSW download for the feeders starts automatically.
→ Save the calibration data for the placement heads in the EEPROM (see section 7.4).
→ Calibrate the nozzle changer.
→ Calibrate the conveyor.
→ Start the production.

Installation Manual, Station Software Version 703.03 01/2011 Edition
3.4 Upgrading from 60x software versions (X-series placement machines)
By upgrading from 60x station software versions, a complete reinstallation/recalibration and mostly also a
hardware rebuilding will be necessary. For this, a corresponding upgrade package is available, that can be
installed by the SIPLACE Service if required.
Ser.No. B001 – B325: cannot be upgraded to the 70x software.
Ser.No. B326 – B599: can only be upgraded to the 70x software by a service team from Munich.
Ser.No. B600 – B751: Update of CAN node and upgrade of the C&P20 nozzle changer to the -04 version
required.
As of Ser.No. B752 the software upgrade to the 70x software can be performed without any hardware
rebuildings.
In the following flowchart all steps are described that have to be performed for the upgrade. At a glance,
these are:
- Downloading the eSW file from the installation CD (directory Upgrade_Preparation) and executing an
eSW download for the placement heads (TQM) with CACCIA from a service PC (not for C&P6/12
placement heads).
- Preparing Box PCs and hardware (se flowchart)
- Installing Windows XP Embedded (recommended) or Windows XP on both Box PCs
- Installing the 703.03 machine computer software for two-computer operation, see chapter 5.
- Installing the Vision computer software, see chapter 6
- Shutting down the machine
- If necessary, performing hardware rebuildings
- Removing the tables
- Switching on the machine again
- Performing an eSW download (see flowchart)
- Performing complete calibration with PCB and head mapping
Note:
- It is also possible to send the mapping files that you have saved before to the SIPLACE
Service. The files will be converted and resent to you. If you re-import the converted
mapping files, no PCB/head mapping has to be performed.
- Starting the production
11 of 54

Installation Manual, Station Software Version 703.03 01/2011 Edition
Flowchart: Upgrading from 60x software versions
12 of 54