SIPLACE 80 F4/F5 1 Retrof itting Instructions for Coplanarity Option Edition 05/99 1.7 Checking the Safety Circuit 1 - 20 NOTE The LE Ds on th e coplan arity proc essin g unit (i n the c ontrol un it) are not activate d …

1 Retrofitting Instructions for Coplanarity Option SIPLACE 80 F4/(F4-6)/F5
1.7 Checking the Safety Circuit Edition 05/99
1 - 19
1.7 Checking the Safety Circuit
DANGER O O O
As with all the retrofitting, the following jobs are to be performed only by the Siemens service engineer.
This also applies for the first time the machine with this option is turned on.
Before you turn the machine on, remove all loose parts and tools from the machine.
The laser shutoff is only to be checked
indirectly , i.e., with the help of the test connector.
To check the sensor cable it is to disconnected directly at the coplanarity processing unit and the test connec-
tor is to connect on in the processing unit. The laser itself (coplanarity sensor) is therefore
not running during
this check.
The laser
shutoff must be checked during all subsequently named interruptions in protection, once with the
key-operated switch locked ("0") and once with the key-operated switch in the service position ("I").
1.7.1 Interruptions in Protection which must be Checked
Perform the following checks as described in detail under “Steps in the Check” in Section 1.7.2:
- Open and close each of the 4 protective covers/hoods:
Input, output, protectve hoods (left and right).
- Actuate and release each of the 3 EMERGENCY OFF buttons: input, output and WPC
- Electrically isolate and connect the 2 component tables from/to the machine.
Sequence while pulling the plug-in connectors -> see WARNING below.
1.7.2 Steps in the Check
The following steps are identical with V 403.04 and V404.01:
● The machine must be turned off.
● Make certain that the key-operated switch is locked.
● Unplug the "sensor cable coplanarity " from the assembly (see Fig. 1.5.6).
● Plug the coplanarity test connectorWRWKHcoplanarity processing unit onto the connector previously
removed (connector configuration and LED allocation: see Fig. 1.5.4).
● Close all of protective devices.
● Turn the machine ON. The control remains “OFF”:
- None of the 4 LEDs on the connected test connector is to light up.

SIPLACE 80 F4/F5 1 Retrofitting Instructions for Coplanarity Option
Edition 05/99 1.7 Checking the Safety Circuit
1 - 20
NOTE
The LEDs on the coplanarity processing unit (in the control unit) are
not activated in the identical manner as
the LEDs on the test connector. Therefore the activation and deactivation of LEDs
must always be con-
firmed at the test connector. The coplanarity sensor is turned back off 20 minutes after the last activation.
Therefore the checks must be performed within this period of time.
CAUTION O
In this case, the calibration procedure subsequently started via SITEST is merely used to turn on the sensor,
i.e., it is NOT to be STORED.
● Load the SITEST program and select:
"Calibrate" -> "Coplanarity" menu -> "Calibrate module" menu.
● Turn the control “ON” (“Start” button).
● The machine will perform a reference run.
● All 4 LEDs on the test connector must light up.
● Now open and close all 4 protective covers one after the other, checking whether the LEDs on the test
connector are activated:
● After one protective cover is opened -> None of the 4 LEDs is to light up.
● After the individual protective cover or all protective covers is/are closed and the “ON” button is acti-
vated ->
all 4 LEDs must light up.
● Press and release all 3 “EMERGENCY OFF” buttons one after the other, checking whether the LEDs on
the test connector are activated:
● After one “EMERGENCY OFF” button is activated -> None of the 4 LEDs is to light up.
● After the “EMERGENCY OFF” button is released and control “ON” is activated -> all 4 LEDs must
light up.
WARNING O O
Always unplug
the round connector first (power supply) of the component changeover table and/or of the
WPC
and then, but only then, the square one (interface connector). During reassembly, plug them back in
in the reverse order. When the machine is turned 21 as in this case - you must ZDLWXQWLOWKH9 control
LED on the component table termination panel goes RII before unplugging the interface connector.
● Unplug the round connector and then the square one on the right-hand component table.
● After the (square) interface connector is pulled out -> none of the 4 LEDs is to light up.
● After the connectors are plugged in (in reverse order) and control is “ON”.
->
All 4 LEDs must light up.
● Follow the same procedure for the component table on the left-hand side of the machine.
● Turn key operating switch to Position "I" (service position) and repeat the procedure described above.
● Afterwards, lock the key-operated switch ("position "0").

1 Retrofitting Instructions for Coplanarity Option SIPLACE 80 F4/(F4-6)/F5
1.8 Configuring the Option (at Line Computer and Station Computer) and Putting It into Service Edition 05/99
1 - 21
● Press the “EMERGENCY OFF” button and turn the machine off.
● Proceed to the steps described in Section 1.8.
1.8 Configuring the Option (at Line Computer and
Station Computer) and Putting It into Service
NOTE
When retrofitting on a SIPLACE F4 machine with software version 402, version 403.0
4 (line computer: SW
V403.xx) must be read in.
For details, consult the pertinent SW version of the “Operating Manual for the UNIX Line Computer”.
1.8.1 Line Computer: Configuring the Coplanarity Option
● Open the configuration editor for SIPLACE 80 F4 or F5.
● During the initial installation: Set the option "Coplanarity".
● During the initial installation or exchange of the coplanarity option (new for old):
Choose the sensor type
:
- In case of V 403.xx: "COPL IC_COP_8" (8 = Default and corresponds to the old
coplanarity module)
- In case of V 404.xx : "COPL IC_COP_17_ILD" (= new coplanarity sensor)
● Store the configuration file.
● Switch to the Data Manager and translate the configuration file (station/<name>.st).
● Check the error message file (.error).
1.8.2 Line Computer: Consistency Check of All Set-Ups
● Activate the “Consistency check” for all set-ups already present:
- In case of V 403.xx: Consistency check must be actuated manually for each set-up present.
- In case of V 404.xx: Consistency is automatically conducted for all set-ups present.
● Check the error files of the consistency check (MK_KE.error).
1.8.3 Line Computer: Activating the Option "Coplanarity" for Individ-
ual Components
● Open the component editor for the desired component and activate the coplanarity measurement.