1 Retrofitting Instructions for Coplanarity Option SIPLACE 80 F4/(F4-6)/F5 1.8 Configuring the Option (at Line C omputer and S tation Computer) and Put ting It into Service Edition 05/99 1 - 21 ● P ress t he “ EMERGENCY …

100%1 / 68
SIPLACE 80 F4/F5 1 Retrofitting Instructions for Coplanarity Option
Edition 05/99 1.7 Checking the Safety Circuit
1 - 20
NOTE
The LEDs on the coplanarity processing unit (in the control unit) are
not activated in the identical manner as
the LEDs on the test connector. Therefore the activation and deactivation of LEDs
must always be con-
firmed at the test connector. The coplanarity sensor is turned back off 20 minutes after the last activation.
Therefore the checks must be performed within this period of time.
CAUTION O
In this case, the calibration procedure subsequently started via SITEST is merely used to turn on the sensor,
i.e., it is NOT to be STORED.
Load the SITEST program and select:
"Calibrate" -> "Coplanarity" menu -> "Calibrate module" menu.
Turn the control ON (Start button).
The machine will perform a reference run.
All 4 LEDs on the test connector must light up.
Now open and close all 4 protective covers one after the other, checking whether the LEDs on the test
connector are activated:
After one protective cover is opened -> None of the 4 LEDs is to light up.
After the individual protective cover or all protective covers is/are closed and the ON button is acti-
vated ->
all 4 LEDs must light up.
Press and release all 3 EMERGENCY OFF buttons one after the other, checking whether the LEDs on
the test connector are activated:
After one EMERGENCY OFF button is activated -> None of the 4 LEDs is to light up.
After the EMERGENCY OFF button is released and control ON is activated -> all 4 LEDs must
light up.
WARNING O O
Always unplug
the round connector first (power supply) of the component changeover table and/or of the
WPC
and then, but only then, the square one (interface connector). During reassembly, plug them back in
in the reverse order. When the machine is turned 21 as in this case - you must ZDLWXQWLOWKH9 control
LED on the component table termination panel goes RII before unplugging the interface connector.
Unplug the round connector and then the square one on the right-hand component table.
After the (square) interface connector is pulled out -> none of the 4 LEDs is to light up.
After the connectors are plugged in (in reverse order) and control is ON.
->
All 4 LEDs must light up.
Follow the same procedure for the component table on the left-hand side of the machine.
Turn key operating switch to Position "I" (service position) and repeat the procedure described above.
Afterwards, lock the key-operated switch ("position "0").
1 Retrofitting Instructions for Coplanarity Option SIPLACE 80 F4/(F4-6)/F5
1.8 Configuring the Option (at Line Computer and Station Computer) and Putting It into Service Edition 05/99
1 - 21
Press the EMERGENCY OFF button and turn the machine off.
Proceed to the steps described in Section 1.8.
1.8 Configuring the Option (at Line Computer and
Station Computer) and Putting It into Service
NOTE
When retrofitting on a SIPLACE F4 machine with software version 402, version 403.0
4 (line computer: SW
V403.xx) must be read in.
For details, consult the pertinent SW version of the Operating Manual for the UNIX Line Computer.
1.8.1 Line Computer: Configuring the Coplanarity Option
Open the configuration editor for SIPLACE 80 F4 or F5.
During the initial installation: Set the option "Coplanarity".
During the initial installation or exchange of the coplanarity option (new for old):
Choose the sensor type
:
- In case of V 403.xx: "COPL IC_COP_8" (8 = Default and corresponds to the old
coplanarity module)
- In case of V 404.xx : "COPL IC_COP_17_ILD" (= new coplanarity sensor)
Store the configuration file.
Switch to the Data Manager and translate the configuration file (station/<name>.st).
Check the error message file (.error).
1.8.2 Line Computer: Consistency Check of All Set-Ups
Activate the Consistency check for all set-ups already present:
- In case of V 403.xx: Consistency check must be actuated manually for each set-up present.
- In case of V 404.xx: Consistency is automatically conducted for all set-ups present.
Check the error files of the consistency check (MK_KE.error).
1.8.3 Line Computer: Activating the Option "Coplanarity" for Individ-
ual Components
Open the component editor for the desired component and activate the coplanarity measurement.
SIPLACE 80 F4/F5 1 Retrofitting Instructions for Coplanarity Option
Edition 05/99 1.8 Configuring the Option (at Line Computer and Station Computer) and Putting It into Service
1 - 22
1.8.4 Line Computer: Activating the Coplanarity Measurement Capa-
bility for the Models
V 403.xx and V 404.xx:
The coplanarity option has already been activated for all measurable models in Siemens Standard Library.
Open the GF file of the relevant, customer-specific models.
Enter the sensor type:
- In case of V 403.xx -> type 8 (as previously for the old module)
- In case of V 404.xx -> type 17
Activate the option field COPLANARITY".
Store the GF file.
1.8.5 Feasibility Test
V 403.xx and V 404.xx:
The feasibility test is automatically performed when a new placement program is specified.
1.8.6 Station Computer: Configuring the Coplanarity Option
1.8.6.1 Procedure for Version 403.04
DANGER O O O
Where retrofitting is involved, no one except the Siemens service engineer is to turn the machine on.
Switch the video multiplexer to MC.
Connect the keyboard appropriate.
With SC, open the file real.ma and SST.ma in the directory D:\Dat\
In the file real.ma edit the positions of the coplanarity sensor:
coplanarity_2_x 444000
coplanarity_2_y 595000
coplanarity_2_z 17000
On the last line in the file sst.ma edit:
Speed factor: 200
Save the data.
Turn the machine off and then back on.
The data for coplanarity is loaded at the station.