00193888-0402_AI_LBO_HFXD3_DE+EN.pdf - 第30页

2 Assembly instructions: Long board option - SIPLACE HF -series / X-series / D3 Long board 02/2007 Edition 30 2.3 Part s required 2.3.1 Assembly kit Long board - SIPL ACE HF series (I tem no.: 001 19672-xx) 2 2.3.2 T ool…

100%1 / 54
Long board 2 Assembly instructions: Long board option - SIPLACE HF-series / X-series / D3
02/2007 Edition
29
2 Assembly instructions:
Long board option -
SIPLACE HF-series / X-series / D3
2.1 Description of the functions
The units supplied for processing area 1 and processing area 2 are prefitted for installation in PCB
conveyors with the stationary conveyor side wall on the right (see drawings on page 49/50). 2
If the machine has the stationary conveyor side wall on the left, some modifications must be made
to the units (see drawings on page 26/27). 2
2.2 Restrictions
The minimum PCB width when using the option is 80 mm. 2
The restrictions for PCB barcodes associated with the PCB barcode option continue to apply (see
Assembly instructions: PCB barcode - HF series, item no.: 00193891-xx). 2
2
2
2
2
2
2
2
2
2
2
2
2
2 Assembly instructions: Long board option - SIPLACE HF-series / X-series / D3 Long board
02/2007 Edition
30
2.3 Parts required
2.3.1 Assembly kit Long board - SIPLACE HF series (Item no.: 00119672-xx)
2
2.3.2 Tools and consumables required
Set of hexagon socket spanners
Set of diagonal cutters
–Torch
Cable ties.
2
2
2
2
Product license for SIPLACE LBO HF series software Item no.: 00191654-xx
Stopper PA1 for Long PCB option Item no.: 00371907-xx
Stopper PA2 for Long PCB option Item no.: 00371909-xx
Assembly gauge LBO HF series Item no.: 03026075-01
Assembly instructions, Long PCB option Item no.: 00193888-xx
Long board 2 Assembly instructions: Long board option - SIPLACE HF-series / X-series / D3
02/2007 Edition
31
2.4 Safety instructions
WARNING
The safety instructions from the “Operational safety” chapter of the user manual and servicing in-
structions take precedence over these instructions.
The SIPLACE placement machines are supplied with mains voltage.
Consequently parts of these systems carry dangerous voltages! This voltage is present at certain
modules inside the machine base, even when the machine is switched off at the main power
switch.
Incorrect handling of the placement machine or touching live parts of the machine can result in
death or severe injury, and considerable damage to equipment. 2
BEFORE starting any work, shut down the operating system correctly, then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed air unit's main valve in the machine
base and vented by actuating the needle valve on the compressed air unit.
There is DANGER for heart pacemaker wearers in the vicinity of the linear motors, as described
in detail in the "Special safety instructions for working in the vicinity of strong magnetic fields"
section of the user manual and service manual.
Always follow the accident prevention regulations, DIN or other standards and special safety
rules applicable in your country.
Pay attention to the information concerning residual voltages in the Operational Safety chapter.
Follow the ESD regulations as described in the operational safety section of the operating
instructions.
During the assembly, always secure the machine to prevent access by other people and to pre-
vent it being switched on again. The procedure is described in the “Locking the machine…” sec-
tion of the user manual.
Working with the SITEST program further increases the risk of accident.
The SITEST program must only be used by authorized and trained personnel.
2
2.4.1 Definitions
2
PLEASE NOTE 2
2
2
2
Tip 2