00197222-02_IM_PCB_Barcode_V2_0_SP2_de_en.pdf - 第6页

PCB Barcode V2.0 SP2 / Installation Manual Ausgabe 03/2012 Edition 2 Scope of Delivery The installation package PCB Barc ode V2.0 SP2 , item no. [00388759-03] contains the following parts: Figure 2-1: Installation packag…

100%1 / 40
PCB Barcode V2.0 SP2 / Installation Manual Ausgabe 03/2012 Edition
1 Brief Description
This installation manual provides instructions on installing the PCB Barcode V2.0 SP2 on the
SIPLACE
®
X-, SX- and DX-series placement machines. It contains information on the scope of
delivery and requirements for successful installation.
After installation, the PCB Barcode mode can be used at the station.
1.1 Safety Instructions
DANGER
Nonobservance of these safety instructions may cause injury to personnel and
damage to the machine!
► Please observe the safety instructions in the user manual of the relevant machine
for all work!
1.1.1 Conventions for the Use of Safety Instructions
This manual contains notes that must be observed to guarantee your personal safety and to avoid
damage to equipment. These notes are highlighted by warning triangles and are indicated as
follows according to the level of risk:
DANGER
Definition
For the purposes of this manual, this indicates that fatal or severe injuries or
considerable damage to property will occur if this hazard warning is not observed.
WARNUNG
Definition
For the purposes of this manual, this indicates that fatal or severe injuries or
considerable damage to equipment may occur if these warning instructions are not
followed.
CAUTION
Definition
For the purposes of this manual, this indicates that minor injuries or damage to property
may occur if this caution is not observed.
NOTICE
Definition
For the purposes of this manual, this note provides information about the product or
indicates a part of the manual that requires particular attention.
5
PCB Barcode V2.0 SP2 / Installation Manual Ausgabe 03/2012 Edition
2 Scope of Delivery
The installation package PCB Barcode V2.0 SP2, item no. [00388759-03] contains the following
parts:
Figure 2-1: Installation package PCB Barcode V2.0 SP1
(1) 1x green USB dongle
(2) 1 x gray USB stick (with drivers and licenses)
(3) 1x USB hub
(4) 1x USB cable
(5) 1x power supply unit
(6) Licenses:
Barcode WdtL
Reading Barcode with PCB Camera
SIPLACE Traceability Station Connection
1x adhesive tape "Klettostar Flausch" (not displayed)
NOTICE
X-series placement machines in two-computer operation
If the placement machine is equipped with a separate Vision computer, you will have to
order two installation packages.
6
PCB Barcode V2.0 SP2 / Installation Manual Ausgabe 03/2012 Edition
3 Prerequisites
– The PCB Barcode has to be installed on both station computer and Vision computer on
X-series placement machines in two-computer operation. For this, two dongles are required,
see Scope of Delivery.
– You have to be logged in as administrator.
– A D: partition has to be available on the station computer / Vision computer.
7