X-Serie S_705.pdf - 第19页

19 Placement heads Standard functions / options SIPLACE SpeedStar (C&P20 P) SIPLACE MultiStar (CPP ) S t andard- functions High-resolution camera, vacuum sensor , force measurement, component sensor , integrated turn…

100%1 / 88
18
Placement heads
Overview
Head modularity
The SIPLACE placement
machines are distinguished
by maximum flexibility in the
production process. This
flexibility is in part due to the
head modularity of the place-
ment machines, which allows
different placement head
variants to be configured to
suit the production require-
ments.
Collect&Place principle
The SIPLACE SpeedStar
operates according to the
Collect&Place principle i.e.
one cycle includes pickup or
"collection" of 20 compo-
nents, their optical centering
on the board and their rota-
tion into the required place-
ment angle and position.
They are then placed gently
and accurately onto the PCB.
This principle is particularly
suitable for high-speed
placement of standard
components.
Pick&Place principle
The high precision SIPLACE
TwinStar, which consists of
two Pick& Place modules of
identical design, coupled to
one another, functions
according to the Pick&Place
principle. Two components
are picked up by the place-
ment head, optically cen-
tered on the way to the
placement position and
rotated into the necessary
placement angle. This princi-
ple is ideally suitable for fast
and precise placement of
special components in the
fine pitch or super fine pitch
field, plus complex and
heavy components which
may need grippers.
Mixed mode
The new SIPLACE MultiStar
uses both the Collect&Place
and the Pick&Place princi-
ple.
Mixed Mode allows com-
bined use of these two
modes, which were previ-
ously separated from one
another, in one placement
cycle.
Control and self-learning
functions
The reliability of the
SIPLACE placement heads
can be enhanced even fur-
ther with various checking
and self-learning functions.
Component sensor
Checks the presence of
the components on the
nozzle before the pickup
and placement process
Digital camera
Checks the position of
each component on the
nozzle. This check is per-
formed in a single step,
with no extra time involved
but with optimum scan-
ning of each individual
component.
Force sensor
Monitors the prescribed
component set-down
force. The sensor stop
procedure enables com-
pensation of height differ-
ences during pickup and
PCB warpage during
placement.
Vacuum sensor
Checks whether the com-
ponent was correctly
picked up or placed.
19
Placement heads
Standard functions / options
SIPLACE SpeedStar (C&P20 P) SIPLACE MultiStar (CPP)
Standard-
functions
High-resolution camera, vacuum
sensor, force measurement,
component sensor, integrated
turning station per segment,
PCB warpage check, individual
image of each component
Standard-
functions
High-resolution camera, vac-
uum sensor, force measure-
ment, component sensor,
integrated turning station per
segment, PCB warpage check,
individual image of each com-
ponent
Options Nozzle changer, special nozzles Options Nozzle changer, special noz-
zles, stationary fine-pitch cam-
era
SIPLACE TwinStar (TH)
Standard-
functions
Stationary fine pitch camera,
vacuum sensor, force measure-
ment, nozzle changer, PCB
warpage check, individual image
of each component
Options Stationary flip chip camera, spe-
cial nozzles, grippers
20
Placement heads
SIPLACE SpeedStar (C&P20 P)
SIPLACE SpeedStar (C&P20 P)
With component camera
type 23
With component camera type
41
Component range
a
a) Please note that the placeable component range is also affected by the pad geometry, the customer-spe-
cific standards, the component packaging tolerances and the component tolerances.
01005 to 2220, Melf, SOT,
SOD
03015 mmto 2220, Melf, SOT,
SOD, Bare-Die, Flip-Chip
Component spec.
Max. height
Min. lead pitch
Min. lead width
Min. ball pitch
Min. ball diameter
Min. dimensions
Max. dimensions
Max. weight
4 mm
0.25 mm
0.1 mm
0.4 mm
0.2 mm
0.4 mm x 0.2 mm
6 mm x 6 mm
1 g
4 mm
0.08 mm
0.03 mm
0.10 mm
0.05 mm
0.12 mm x 0.12 mm
6 mm x 6 mm
1 g
Programmable set-down
force
1.3 - 4.5 N 1.3 - 4.5 N
Nozzle types 40xx 40xx
X/Y accuracy
b
b) The SIPLACE benchmark value is measured during the machine acceptance tests. It corresponds to the
conditions set out in the SIPLACE scope of service and supply.
± 36 µm/3
± 48 µm/4
± 36 µm/3
± 48 µm/4
Angular accuracy ± 0.5° / 3
± 0.7° / 4
± 0.5° / 3
± 0.7° / 4
Illumination level 5 5
Possible illumination
level settings
256
5
256
5