00195813-04_IM_SSW_605.03_DE EN.pdf - 第22页
Installation Manual, Station Software Version 605.03 10/2010 Edition 4.5 Network configuration Station computer Machine controller 10Base-T 100Base-T Private network between station computer, Vision computer (op tional) …

Installation Manual, Station Software Version 605.03 10/2010 Edition
21 of 50
4.4.1 Station computer
Name
SIMATIC Box PC 627
CPU / clock frequency
Pentium M / 2 GHz
RAM
1 GB
Hard disk
40 GB
External DVD drive
Yes
Serial interfaces
1
USB interfaces
and external USB hub
Yes
Network
2x 100 Mbit
Table 4-10: Station computer hardware (configuration of SIPLACE CA-series)
4.4.2 Machine controller
Name
SIMATIC Box PC 627
CPU / clock frequency
Pentium M / 2 GHz
RAM
1 GB
Hard disk
40 GB
External DVD drive
Yes
Serial interfaces
1
USB interfaces
and external USB hub
Yes
Network
2x 100 Mbit
Table 4-11: Machine controller hardware (configuration of SIPLACE CA-series)
4.4.3 Vision computer (optional)
Name
SIMATIC Box PC 627
CPU / clock frequency
Pentium M / 2 GHz
RAM
1 GB
Hard disk
40 GB
External DVD drive
Yes
Serial interfaces
1
USB interfaces and external USB hub
Yes
Network
2x 100 MBit
Table 4-12: Vision computer hardware (optional for SIPLACE CA3 with 3D coplanarity sensor)

Installation Manual, Station Software Version 605.03 10/2010 Edition
4.5 Network configuration
Station computer
Machine controller
10Base-T
100Base-T
Private network between
station computer,
Vision computer (optional)
and machine controller
SIPLACE LAN
SIPLACE Pro
Twisted Pair TP
(100 MB)
Twisted Pair TP
(10 MB)
Vision computer
(optional)
100Base-T
Fig. 4-5: Network connections between the machine and SIPLACE Pro
A separate private network (100 Mbit) is set up between the station computer (and optionally the Vision
computer) and the machine controller via a subnet mask.
Fixed IP addresses for the station computer, Vision computer and machine controller can thus be assigned
for all SIPLACE machines. These IP addresses are not known outside the private network, for instance in
the SIPLACE LAN or customer LAN.
These IP addresses need not be further configured by the operator while the station software is being
installed.
IP address, station computer 192.168.255.249
IP address, machine controller 192.168.255.250
Vision computer IP Address 192.168.255.251
Subnet mask, station computer/machine controller 255.255.255.248
IP address range, SIPLACE LAN or
IP address range, customer LAN
172.22.xxx.xxx
is configured on-site
Subnet mask for SIPLACE-LAN or
subnet mask for customer LAN
255.255.0.0
is configured on-site
Table 4-13: Network configuration
22 of 50

Installation Manual, Station Software Version 605.03 10/2010 Edition
5 Installing the station software
Note:
The operation system must be installed on the machine controller and Vision computer
before installing the station software.
5.1 Installation sequence
See section 5.2.
See section 5.3.
See the separate installation manual for installing the "Windows XP operating
system" (item no. 00194575-xx)
For calibrating the touchscreen, see sections 5.4.3.
See sections 5.4 and 5.5.
See section 5.6.
23 of 50