26 JAKA Zu 12 v 1.0 24V 0V P8 E m e rge nc y s t op sw i tch - S ingle s w it c h EI 1 2 SI 1 2 V+ V+ V- 0V 24V P8 Fig 4-5 24V 0V P8 E m e rg e nc y s to p - m ul ti - wa y s w i t ch EI 1 2 SI 1 2 V+ V+ V- 0V 24V P8 Fig…

100%1 / 56
JAKA Zu 12 v1.0 25
V+ V-
24V
0V
P8
Internal power
supply
V+
V-
24V
0V
P8
External power
supply
+-
Fi
gure 4-3
The electrical cabinet has a dedicated safety I/O interface, and the user can configure two functions:
emergency stop and protection stop. The function description is detailed in section 4.3.7. Here are some
examples of how safe I / O interface.
1. Factory configuration.
Users can use the robot without any additional safety equipment. If EI1~2 and SI1~2 are both connected to
V+, V+ is connected to 24V, and V- is connected to 0V, it indicates that 24V power is provided inside the
electrical cabinet. As shown in Figure 4-4.
24V
0V
P8
EI
1 2
SI
1 2
V+
V+ V-
0V
24V
P8
Fi
gure 4-4
2Connect the emergency stop switch.
The user needs to use one or more additional emergency stop or guard stop switches, please refer to Figure
4-5 and Figure 4-6 for wiring. Figure 4-5 and Figure 4-6 show how to use one or more emergency stop
switches. The example uses an internal 24V power supply and the user can also use an external 24V power
supply.
26 JAKA Zu 12 v1.0
24V
0V
P8
Emergency stop
switch-Single switch
EI
1 2
SI
1 2
V+
V+ V-
0V
24V
P8
Fig
4-5
24V
0V
P8
Emergency stop
-
multi-way switch
EI
1 2
SI
1
2
V+
V+ V-
0V
24V
P8
Fig 4-6
3. Connect the protective stop switch
Protective stop function, support automatic recovery. The electrical cabinet door switch is an application
case of the protection stop device, and the robot stops when the electrical cabinet door is opened. The wiring
diagram is shown in Figure 4-7.
Fig
4-7
JAKA Zu 12 v1.0 27
4.3.2 Digital Input (DI)
Fig
4-8
The electrical cabinet is equipped with 16 digital PNP type input(Active high) (DI1 ~ DI16) to support
isolated signal input. The level signal satisfies the IEC61131-2 (Type1/2/3) standard and is used to detect the
input signal level status.
V+ Voltage
Low range High range
24V
011V 1524V
The V+ interface supports external 10~35V power input. The factory default uses internal 24V power
supply. The high level range is 15~24V, and the low level range is 0~11V.
Users can also connect DIx to V+ directly.
Different types of input signals have different connections. The specific connection methods are as follows:
a) Dry contact signal as input
Fi
gure 4-9
During dry contact input, one of the wires is connected to V + and the other wire is connected to DIx. When
the circuit is on (as shown in the figure, the switch or relay is closed), the corresponding LED turns on. You can
also see the DIx status on the APP interface
b) PNP type signal as input