i3070+s5i_ReplacePowerSupply+ed2.pdf.pdf - 第21页

i3070 4-mod Inline System (E9986E) Replacing the Power Supply 21 14 Connect a new cable labeled – fr om the Omron power supply to TB-2. Pr oceed to Completing the installation . Installing the Cosel 6. 4 A A C/DC power s…

100%1 / 24
20 Replacing the Power Supply
i3070 4-mod Inline System (E9986E)
11 Locate the cable labeled F1+ (TB-2 to F-5). Disconnect the cable from TB-2
and connect it to K-B.
12 Connect a new cable labeled F2+ to K-B. Connect the other end to TB-2, in the
space previously occupied by F1+.
13 At TB-1, move the cable labeled L4 to the space previously occupied by L5
which was removed in step 5.
TB-2
K-B
TB-2
K-B
TB-1
i3070 4-mod Inline System (E9986E)
Replacing the Power Supply 21
14 Connect a new cable labeled from the Omron power supply to TB-2.
Proceed to Completing the installation.
Installing the Cosel 6.4 A AC/DC power supply
If installing the Cosel 6.4 A AC/DC power supply, follow step 15 through step 18.
15 Install the bracket and mount the new Cosel 6.4 A AC/DC power supply.
16 Connect the cables labeled ST+, ST-, E, N1, L7 (formerly from PS3) to the
Cosel power supply. Tighten the screws to secure the cables and close the
protective cover.
TB-2
Cosel 6.4 A AC/DC power
supply with bracket
protective cover
22 Replacing the Power Supply
i3070 4-mod Inline System (E9986E)
Completing the installation
17 Make sure all the cables are routed properly in the trunking, then close all the
trunking covers.
18 Ensure all connections are correct before securing the system’s top cover.